In high-intensity areas, structures designed according to the elastic story drift ratio limit specified in the national standard Technical Specification for Concrete Structures of Tall Buildings often require numerous vertical components with large cross-sectional dimensions, which adversely affect building functionality and economy. To investigate the rationality of relaxing the story drift ratio limit as recommended in a group standard—Standard for Performance‑based Seismic Design of Building Structures —three shear wall structures with progressively reduced stiffness were designed based on the standards, considering the high-intensity region of Kashgar, Xinjiang, as an engineering case study. This study compared the overall structural, economic, and carbon emission indices of the three structures. Further, a deformation-based structural seismic performance evaluation method was employed to quantify the structural component damage level and repair cost under rare earthquakes. The results indicate that all three structures exhibit desirable yielding mechanisms and satisfactory seismic resilience under rare earthquakes; meanwhile, the structures designed with relaxed story drift ratio limits demonstrate superior economic efficiency and carbon reduction benefits. The elastic story drift ratio limit for shear wall structures in high-intensity areas can be relaxed to 1/500 under frequent earthquakes.
WANGYayong. Lessons learnt from building damages in the Wenchuan earthquake: seismic concept design of buildings[J]. Journal of Building Structures, 2008, 29(4): 20-25.
YANPeilei, SUNBaitao, WANGMingzhen. Seismic damage of building structures in Luyang Town during Lushan earthquake with a magnitude of 7.0[J]. China Civil Engineering Journal, 2014, 47(11): 39-44.
HANXiaolei, ZHANGLei, YANGGuang, et al. Comparative study on story drift limits of RC structures under earthquakes between Chinese codes and American codes[J]. China Civil Engineering Journal, 2020, 53(1): 31-38.
Ministry of Housing and Urban-Rural Development of the People’s Republic of China. Technical specification for concrete structures of tall building: JGJ 3—2010 [S]. Beijing: China Architecture & Building Press, 2011.
FANGXiaodan. Basis and background of revision of DBJ/T 15-92—2021 Technical specification for concrete structures of tall buildings [J]. Journal of Building Structures, 2021, 42(9): 172-188.
LIKun, SHIQingxuan, GUOZhifeng, et al. Calculation and discussion of physical inter-story displacement for reinforced concrete shear wall structures[J]. China Civil Engineering Journal, 2013, 46(): 86-92.
China Association of Engineering Consultants. Standard for performance-based seismic design for building structures: T/CECA 20024—2022 [S]. Beijing: China Building Materials Press, 2022.
XINDingkang, HUShaolong, JIANGLixue, et al. Limit value of interstory drift of reinforced concrete super highrise buildings[J]. Journal of Building Structures, 2000, 21(3): 10-15.
DAIJinhua, HANXiaolei, LINShengyi. Study of performance-based seismic design method for reinforced concrete structures[J]. China Civil Engineering Journal, 2011, 44(5): 1-5.
Ministry of Construction of the People's Republic of China,General Administration of Quality Supervision, Inspection and Quarantine of the People’s Republic of China. Code for seismic design of buildings: GB 50011—2001 [S].2008 ed. Beijing: China Architecture & Building Press, 2010.
Xinjiang Construction Cost Information Nets. Comprehensive price information for construction projects in December 2022 in Kashgar region[EB/OL]. [2023-01-10].
Ministry of Housing and Urban-Rural Development of the People’s Republic of China. Standard for building carbon emission calculation: GB/T 51366—2019 [S]. Beijing: China Architecture & Building Press, 2019.
JIJing, LIANGXiaomin, FUHao, et al. Spectral characteristics of ground motions in the original sites of Kashi, Xinjiang[J]. China Earthquake Engineering Journal, 2023, 45(6): 1425-1431.
State Administration for Market Regulation, Standardization Administration of the People’s Republic of China. Standard for seismic resilience assessment of buildings: GB/T 38591—2020 [S]. Beijing: Standards Press of China, 2020.