U-shaped dampers are efficient energy dissipation devices that have been widely used in various engineering applications. To improve the damping performance of U-shaped dampers in seismic isolation structures, a novel damping steel with superior mechanical properties was used to fabricate the dampers. The material properties, including yield strength, tensile strength, and elastic modulus, were determined. Five U-shaped dampers made of this novel damping steel were manufactured, and hysteretic performance tests were conducted. The test results indicate that under cyclic loading, the dampers exhibit stable hysteretic behavior and full hysteretic loops. Based on these findings, a finite element model of the U-shaped damper was developed to simulate its mechanical behavior under cyclic loading. The effects of plate thickness, plate width, plate spacing, and the length of the straight segment of the fillet on damper performance were then investigated. The parametric analysis results indicate that the U-shaped damper made of the novel damping steel possesses excellent mechanical properties and favorable hysteretic performance, providing a reference for the optimal design of such dampers.
CHENGXuansheng, JIAChuansheng, DUXiuli. The application of energy dissipation technology in seismic strengthening[J]. China Civil Engineering Journal, 2012, 45(): 253-257.
YELieping, LUXinzheng, MAQianli, et al. Influence of post-yielding stiffness to seismic response of building structures[J]. Journal of Building Structures, 2009, 30(2): 17-29.
[5]
OHS H, SONGS H, LEES H, et al. Experimental study of seismic performance of base-isolated frames with U-shaped hysteretic energy-dissipating devices[J]. Engineering Structures, 2013, 56: 2014-2027.
[6]
ATASEVERK, CELIKO C, YUKSELE. Development and cyclic behavior of U-shaped steel dampers with perforated and nonparallel arm configurations[J]. International Journal of Steel Structures, 2018, 18(5): 1741-1753.
[7]
KISHIKIS, OHKAWARAY, YAMADAS, et al. Experimental evaluation of cyclic deformation capacity of U-shaped steel dampers for base-isolated structures[J]. Journal of Structural and Construction Engineering (Transactions of AIJ), 2008, 73(624): 333-340.
CHONGXun, HOULinbing, CHENXi, et al. Study on mechanical performance and numerical simulation analysis method of U-shaped metal damper[J]. Building Structure, 2021, 51(1): 114-120.
YUTianhao, ZHANGChao, DINGChao, et al. Working mechanism and finite element analysis of a three-dimensional isolation device with disc springs-U-shaped dampers[J]. Journal of Civil Engineering and Management, 2023, 40(1): 124-129, 135.
SHAOHao, YANGMingfei, WANGXin, et al. Research on design and numerical analysis of the constrained U-shaped soft steel damper[J]. Earthquake Resistant Engineering and Retrofitting, 2019, 41(1): 62-69.
YANGMingfei, ZHAChencheng. Position optimization of annular shear soft steel dampers in controlled structures[J]. Journal of Anhui University of Science and Technology (Natural Science), 2023, 43(5): 24-29.
FENGHuan, ZHOUFangyuan, YunhuiLÜ. Experimental study on mechanical properties of butterfly metallic damper and its application[J]. China Civil Engineering Journal, 2024, 57(5): 15-26, 85.
ZHUXiang, WANGWeixu, LIWanrun, et al. Study on the mechanical properties of collision avoidance and energy absorption device based on anti-impact U-shaped damper[J]. Engineering Mechanics, 2026, 43(2): 180-193.
DUHongkai, HANMiao, YANWeiming. Study on the calculation method of me chanical characteristics for constrained U-shaped steel plates[J]. China Civil Engineering Journal, 2014, 47(): 158-163.
DUHongkai, HANMiao, YANWeiming, et al. Mechanical properties analysis of U-shaped steel plates of different hardness and numbers of layers[J]. Engineering Mechanics, 2016, 33(): 101-106.
HANMiao, DUANYanbiao, DUHongkai. Analysis of simulating hysteresis curve of U-shape mild steel damper based on the improved R-O model[J]. Journal of Beijing University of Civil Engineering and Architecture, 2016, 32(3): 43-48.
[30]
DENGK L, PANP, WANGC Y. Development of crawler steel damper for bridges[J]. Journal of Constructional Steel Research, 2013, 85: 140-150.
DENGKailai, PANPeng, SUYukun, et al. Experimental study on lateral performance of slotted U-shaped steel damper[J]. Journal of Vibration and Shock, 2015, 34(12): 157-163.
SUYukun, PANPeng, DENGKailai, et al. Mechanical properties of U-shaped steel damper subjected to bi-axial ground motions[J]. Journal of Building Structures, 2014, 35(8): 44-49.
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of China. Metallic materials—tensile testing—part 1: method of test at room temperature:GB/T 228.1—2010 [S]. Beijing: China Standards Press, 2010.
[37]
Federal Emergency Management Agency. Interim testing protocols for determining the seismic performance characteristics of structural and nonstructural components: FEMA 461[R]. Washington, D.C.: Federal Emergency Management Agency, 2007.
ZHAOZhenzhen, ZHANGAijun, HEBin. Study on mechanics formula deduction and damping performance of U-shaped metal damper[J]. Structural Engineers, 2017, 33(2): 143-150.
[40]
徐秉业. 应用弹塑性力学[M]. 北京: 清华大学出版社, 1995.
[41]
XUBingye. Applied elastic-plastic mechanics[M]. Beijing: Tsinghua University Press, 1995.