A composite passive control system (CPCS) that integrates base isolation and intertower energy dissipation is effective in controlling the seismic response of large-chassis twin-tower structures. To refine the performance-based seismic design of the CPCS, the intertower connections are modeled as Kelvin dampers to capture their energy-dissipation characteristics. Furthermore, a direct displacement-based design approach considering the higher-mode effects is proposed without the need of complicated iterative calculations. In this displacement-based framework, the performance objectives are first defined based on the characteristics of the structural system. Then, a relationship between the additional equivalent damping ratio and the structural period is established to improve the accuracy and efficiency of the damping calculations. Therefore, the equivalent single-degree-of-freedom substructure system of the multi-degree-of-freedom system is obtained to estimate seismic demand. Finally, the optimal damper layout is obtained considering both the floor displacements and the additional damping ratios. Design case studies demonstrate that the proposed method meets interstory drift ratio limits without iteration. The elastic and elastoplastic time-history analyses both confirm that the CPCS significantly enhances the seismic capacity of the structure to satisfy the performance objectives of “no damage under moderate earthquakes, repairable under rare earthquakes, and no collapse under extremely rare earthquakes,” and thus verify the scientific basis and effectiveness of the proposed design method.
现代城市建设中,大底盘塔楼结构凭借独特的空间布局与较高的土地利用效率,成为城市标志性建筑之一。然而,该类结构存在竖向不规则问题,刚度突变位置易产生应力集中,甚至发生构件破坏。为提升其抗震能力,学者已提出多种技术手段,例如设置竖向转换层[1]与隔震层[2]来削弱地震作用。针对隔震层位置与参数的影响,已有学者开展振动台试验及抗震韧性评价研究[3-4],相关手段在一定程度上改善了结构抗震表现,但仍存在一定局限[5]。塔楼相互独立布置时,不仅易诱发结构扭转与变形效应[6],塔楼间距较小时还会发生塔楼碰撞,造成严重结构损伤。针对该问题,现有研究提出在相邻塔楼间布设控制装置[7],研究表明,在连廊与主体结构之间合理布置阻尼器可有效减小支座位移响应。在此基础上,复合被动控制体系(Composite Passive Control System,CPCS)得到发展,该体系联合隔震层与阻尼器,协同实现地震能量的隔离与耗散,显著降低结构动力响应。现有针对CPCS振动特性[8]、参数优化[9]与控制效果[10]的系统分析表明,CPCS为复杂建筑抗震性能提升开辟了新的技术路径[11]。但目前针对大底盘双塔楼这一特殊结构形式,尚缺乏系统的抗震设计研究,亟需提出针对性的分析与设计方法。
本文开展大底盘双塔楼CPCS直接基于位移的设计方法研究,旨在揭示该体系在地震作用下的动力特性与抗震性能,建立一套适用于该类复杂结构的设计策略。研究从理论分析、结构设计、性能验证三个维度开展,采用子结构单自由度体系(Single Degree of Freedom,SDOF)简化方法,以克服大底盘双塔楼结构的设计复杂性,重点解决该类结构性能目标确定、附加阻尼比求解、设计流程构建等关键科学问题。
XilinLü, ZhangCuiqiang, LIJianbao, et al. Seismic performance of multi-tower structure with large podium and overlapping column[J]. Journal of Building Structures, 2011, 32(6): 10-17.
[3]
ZhangS R, HeJ M, LiuL K, et al. Energy research of three-adjacent structures connected by Kelvin-type dampers based on power flow[J]. Structures, 2023, 51: 1670-1683.
[4]
WangX Y, XieL L, LiuQ M, et al. Resilience-based seismic design of inter-story isolated multi-towers built on large chassis[J]. Structures, 2023, 50: 884-895.
YangCantian, WangXinyu, LiAiqun, et al. Seismic resilience comparison between tall building with isolated inter-storey multi-tower base and one with an isolated large chassis[J]. Engineering Mechanics, 2024, 41(8): 228-237.
ZhangShangrong, DengHairui, HuYuchen, et al. Natural vibration characteristics and the stochastic response of inter-story isolation structures considering the SSI effect[J]. China Earthquake Engineering Journal, 2023, 45(3): 651-660.
[9]
WangL, LeiH G. Structural analysis of a multi-tower building with a large chassis in a business district[J]. IOP Conference Series: Earth and Environmental Science, 2021, 647(1): 012175.
[10]
KangX, LiS, YanC, et al. Enhancing the seismic performance of adjacent building structures based on TVMD and NSAD[J]. Buildings, 2023, 13(8): 2049.
[11]
ZhangS R, HuY C, LiuX Y, et al. Hybrid isolation strategy for seismically isolated multi-tower building with a large podium[J]. International Journal of Structural Stability and Dynamics, 2022, 22(6): 2250061.
[12]
ZhangS R, HuY C, ZhangC, et al. Performance-based compositive passive control analysis of multi-tower building with chassis: optimization of Kelvin-Voigt dampers[J]. Buildings, 2022, 12(2): 137-137.
HuanLü, ZhangShangrong, TangXiang, et al. Seismic control research on large chassis twin towersbased on power flow theory[J]. Journal of Natural Disasters, 2024, 33(5): 188-198.
[15]
LiuY, LiJ B, LiG. Nonlinear seismic assessment for nuclear power plants with structural-geotechnical hybrid isolation strategy[J]. Structures, 2024, 67: 107020.
[16]
WangB S, HeH X, YanW M. Seismic performance design of energy-dissipated structure system based on damage control and time-varying damping ratio[J]. Soil dynamics and earthquake engineering, 2021, 151: 106996.
[17]
PriestleyM J N. Direct displacement-based design of precast/prestressed concrete buildings[J]. PCI Journal, 2002, 47(6): 66-79.
[18]
MedhekarM S, KennedyD J L. Displacement-based seismic design of buildings-theory[J]. Engineering Structures, 2000, 22(3): 201-209.
LiSihan, CaiXiaoguang, JingLiping, et al. Displacement-based seismic design methods of a modular reinforced soil retaining wall[J]. China Earthquake Engineering Journal, 2023, 45(5): 1066-1074.
[21]
DomenicoD D, GandelliE, GioittaA. Displacement-based design procedure for the seismic retrofit of existing buildings with self-centering dissipative braces[J]. Structures, 2024, 62: 106174.
[22]
LukeV D B, MohsenK, DimitriosV, et al. A risk-based evaluation of direct displacement-based design[J]. Bulletin of Earthquake Engineering, 2022, 20(12): 6611-6633.
[23]
LiF, WangL, WuY. Seismic response reduction analysis of large chassis base-isolated structure under long-period ground motions[J]. Earthquake Research Advances, 2021, 1(2): 49-56.
WuQiaoyun, LiuZiliang, YanHuichao, et al. Experimental study on the influence of the position change of the middle isolation layer on the control effect of the hybrid passive control system[J]. Journal of Vibration Engineering, 2022, 35(1): 1-12.
[26]
GB/T 51408-2021 建筑隔震设计标准 [S].
[27]
GB/T 51408-2021 Standard for seismic isolation design of building [S].
[28]
XiaoY, ZhouY, HanZ Q. Efficient direct displacement-based seismic design approach for structures with viscoelastic dampers[J]. Structures, 2021, 29: 1699-1708.