Sun Yat-sen Memorial Hall in Guangzhou, a nationally protected key cultural relic with nearly a century of history, features a distinctive large-span octagonal steel roof truss system that lends the building a solemn and dignified appearance. The dynamic performance of this elevated, large-span octagonal steel roof truss system under earthquake and wind loads directly governs the structural safety of the Memorial Hall. To evaluate its safety under extreme loads, the structural characteristics of the steel roof truss system were analyzed on the basis of historical archives and 3D laser scanning data, and an ABAQUS finite element model was calibrated using ambient vibration test results. Three ground motion records and wind loads with return periods of 10, 50, and 100 years were then selected as inputs for nonlinear time-history analysis, and the coupled wind-earthquake response of the structure was investigated using nonlinear dynamic time-history analysis. The results show that under a peak ground acceleration of 0.4g and a 100-year return period wind load, the maximum interstory drift of the octagonal steel roof truss structure is 1/125, which does not exceed the safety limit. Wind loads contribute markedly to the displacement increment; under the 100-year return period wind load, the root mean square displacement reaches 13.05 mm, far exceeding the displacement response caused by seismic action alone. These findings indicate that the steel roof truss structure possesses adequate wind and seismic resistance, providing important technical support for the protection and safety assessment of historic buildings.
增强频域分解法(EFDD)通过奇异值分解(Singular Value Decomposition,SVD)将响应谱密度函数分解为一系列单自由度系统的自功率谱,其峰值对应结构的固有频率。随后,对SVD分解得到的单自由度功率谱进行傅里叶逆变换(Inverse Fast Fourier Transform,IFFT),以获得自由衰减函数,并利用对数衰减法计算阻尼比。
WangLong, ZhengJianguo, QianChunyu, et al. Present situation and prospect on seismic and anti-vibration technology of ancient buildings[J]. Journal of Natural Disasters, 2024, 33(2): 1-17.
XueJianyang. Preface of “anti-seismic and strengthening protection of ancient architecture structure”[J]. Journal of Xi'an University of Architecture & Technology (Natural Science Edition), 2024, 56(5): 630.
ZhengJianguo, XuJian, QianChunyu, et al. Research on several key technologies of earthquake resistance and vibration control of ancient buildings[J]. China Civil Engineering Journal, 2023, 56(1): 1-17.
ZhouQian, YanWeiming, YangXiaosen, et al. Damage of ancient Chinese architecture caused by the Wenchuan earthquake[J]. Sciences of Conservation and Archaeology, 2010, 22(1): 37-45.
PanYi, TangLina, WangHuiqin, et al. Investigation and analysis of damage to ancient buildings in Lushan MS7.0 earthquake[J]. Earthquke Engineering and Engineering Dynamics, 2014, 34(1): 140-146.
PanYi, LiLingjiao, YaoYunyi, et al. Evaluation methods for post-earthquake damage state of ancient masonry buildings[J]. Journal of Southwest Jiaotong University, 2016, 51(4): 704-713.
XueJianyang, XuDan, RenGuoqi, et al. Shake table test on seismic performance of column and tie wooden structure in traditional residence[J]. China Civil Engineering Journal, 2019, 52(12): 1-10.
YuanJianli. Study on corresponding relation between seismic intensity and damage degree of ancient masonry pagodas[J]. Earthquake Engineering and Engineering Vibration, 2013, 33(2): 163-167.
[19]
Diz-MelladoE, Mascort-AlbeaE J, Romero-HernándezR, et al. Non-destructive testing and finite element method integrated procedure for heritage diagnosis: the Seville Cathedral case study[J]. Journal of Building Engineering, 2021, 37: 102134.
[20]
GünaydinM, GençA F, AltunışıkA C, et al. Structural condition assessment of a historical masonry school building using experimental and numerical methods[J]. Journal of Civil Structural Health Monitoring, 2022, 12(5): 1083-1113.
ChenPing, ZhaoDong, YaoQianfeng. An exploration of the aseismic behavior of Xi'an Xiaoyan Pagoda[J]. Journal of Xi'an University of Architecture & Technology (Natural Science Edition), 1999, 31(2): 149-151.
YangNa, LiuWei, ZhangShuhui, et al. Dynamic performance analysis of Kaiyuan Pagoda based on ambient vibration test[J]. China Civil Engineering Journal, 2021, 54(9): 79-87
LiuWei, YangNa, BaiFan, et al. Research on the dynamic characteristics of Tibetan ancient city wall based on ambient excitation[J]. China Civil Engineering Journal, 2021, 54(4): 45-56.
[29]
Kalkan OkurE, AltunışıKA C, Yesevi OkurF, et al. Dynamic response of a traditional hımış mansion using updated FE model with operational modal testing[J]. Journal of Building Engineering, 2021, 43: 103060.
[30]
GB/T 50011—2010 建筑抗震设计标准 [S].
[31]
GB/T 50011—2010 Code for seismic design of buildings [S].
[32]
DavenportA G. Gust loading factors[J]. Journal of the Structural Division, ASCE, 1967,93(ST3): 11-34.
[33]
GB 50009—2012 建筑结构荷载规范 [S].
[34]
GB 50009—2012 Load code for the design of building structures [S].
LiuYang, LiHongnan, LiChao, et al. The study on the vulnerability of the concrete stilled steel tubular frame with buckling-restrained braces structure under the coupling of wind and earthquake[J]. China Civil Engineering Journal, 2019, 52(2): 56-65.
[39]
SmithV, MahmoudH. Multihazard assessment of wind turbine towers under simultaneous application of wind, operation, and seismic loads[J]. Journal of Performance of Constructed Facilities, 2016, 30(6): 04016043.
[40]
JGJ 7—2010 空间网格结构技术规程 [S].
[41]
JGJ 7—2010 Technical specification for space frame structures [S].