Underground complex structures play an important role in enhancing urban underground space utilization, but their special composite structural forms and high-level functional resilience requirements create an urgent need for research on seismic performance evaluation and resilience enhancement technologies. With its inertial amplification and tuning-based vibration absorption mechanisms, the inerter system can flexibly adjust the inertial characteristics of the controlled structure and thereby govern its dynamic response. Building on this principle, this paper proposes an inerter-based isolation system applicable to underground complex structures and clarifies its installation methods, simulation approaches, and parameter design procedures. Using a typical underground complex structure as the engineering background, numerical simulation analyses were conducted on the soil-inerter isolation system-complex interaction system, yielding recommended design parameters for the isolation system. The results show that the proposed design procedure can effectively correlate design parameters with the structural response of the complex, thereby achieving the seismic design objectives. The system can effectively control the acceleration, displacement, and stress responses of the underground complex structure and, compared with conventional isolation schemes, can simultaneously satisfy the multi-objective coordinated control requirements of both the complex structure and the isolation layer. Moreover, it substantially controls the seismic response of the superstructure above the complex without degrading that of the underground portion.
DongJie, SunPing, ZhangPeng, et al. The progress and prospects of underground space development and construction in Qingdao[J]. Resources Survey & Environment, 2024, 45(3): 264-280.
XuYajie, ChenXiangsheng. Current situation and prospect of comprehensive development of underground space in metro area[J]. Chinese Journal of Underground Space and Engineering, 2023, 19(1): 1-12, 21.
KuangWenjie, ZhouHao, BuDan, et al. Analysis and design of key problems of super long span commercial complex structure[J]. Building Structure, 2023, 53(S2): 459-464.
[7]
AnJ H, FengF Q, ZhangY H, et al. Response displacement method for seismic calculation of subway station complex structure of TOD mode[J]. Buildings, 2023, 13(12): 2987.
ShenAndi, ChenQingjun. Seismic response of underground complex subjected to different types of ground motions[J]. Chinese Quarterly of Mechanics, 2018, 39(3): 562-572.
[10]
QianQ H. Present state, problems and development trends of urban underground space in China[J]. Tunnelling and Underground Space Technology, 2016, 55: 280-289.
[11]
ZhouY, ChenQ D, WuH, et al. Seismic performance of a frame-supported shear wall over-track building through shaking table test[J]. The Structural Design of Tall and Special Buildings, 2024, 33(9): e2098.
[12]
PanC, ZhangR F. Design of structure with inerter system based on stochastic response mitigation ratio[J]. Structural Control and Health Monitoring, 2018, 25(6): e2169.
[13]
LazarI F, NeildS A, WaggD J. Vibration suppression of cables using tuned inerter dampers[J]. Engineering Structures, 2016, 122: 62-71.
ZhangRuifu, WuMinjun, PanChao. Discussion on the basic concept and design paradigm of inerter system[J]. Journal of Vibration Engineering, 2024, 37(11): 1848-1861.
[18]
DeastraP, WaggD J, SimsN D, et al. Experimental shake table validation of damping behaviour in inerter-based dampers[J]. Bulletin of Earthquake Engineering, 2023, 21(3): 1389-1409.
HeZhiming, TangZhenyun, DongXiaohui, et al. Study on the damping performance of tuned mass damper inerter for nuclear containment structures[J]. Earthquake Engineering and Engineering Vibration, 2025, 45(1): 51-60.
ShiYan, ShiYunshan, HanJianping, et al. Seismic damage control of continuous rigid frame bridges based on thecombined seismic isolation strategy with inerter system[J/OL]. Journal of Vibration Engineering,2025-03-18.
[23]
ZhaoZ P, TangY C, HongN, et al. Interaction-performance-driven design of negative-stiffness friction pendulum systems for aboveground structure-connected underground structure-soil system with ground motion effects[J]. Journal of Building Engineering, 2024, 88: 108970.
LinZhibo. Application and analysis of isolation technology in building structure of metro[J]. Fujian Architecture & Construction, 2017(7): 97-103, 134.
HuangYu, YeWeimin, TangYiqun, et al. Characteristic analysis for seismic ground response of soft soils in Shanghai[J]. Chinese Journal of Underground Space and Engineering, 2005, 1(5): 773-778.
[28]
HuangY, YeW M, ChenZ C. Seismic response analysis of the deep saturated soil deposits in Shanghai[J]. Environmental Geology, 2009, 56(6): 1163-1169.
LouMenglin, ShaoXingang. Several problems in seismic response calculation of soil layer with deep deposit using general software[J]. Journal of Vibration and Shock, 2015, 34(4): 63-68, 109.
ZhouQiang, ChenSi, WangYunlong, et al. Seismic response of subway station structure in liquefiable silt layer[J]. China Earthquake Engineering Journal, 2024, 46(6): 1331-1344.
[33]
LiW T, ChenQ J. Effect of vertical ground motions and overburden depth on the seismic responses of large underground structures[J]. Engineering Structures, 2020, 205: 110073.