To mitigate adverse effects, such as premature failure of isolation bearings caused by excessive torsional loads in base-isolated structures, codes worldwide have specified limits for the eccentricity of the isolation layer. This study performs a comparative analysis of the physical significance of three existing methods for calculating the eccentricity of base-isolated structures. A response spectrum-based method with effective stiffness correction is proposed to determine the effective stiffness of bearings in eccentricity calculations. Analytical models with different parameters and case studies of actual structures are used to compare the proposed method with the three existing methods. The results show that iterative correction of the effective stiffness of isolation bearings effectively captures the differences in the maximum deformation of individual bearings caused by torsion. The corrected stiffness center differs from the uncorrected one by up to 183 mm. Case studies indicate that the structural period decreases by approximately 5% after applying the effective stiffness correction. The eccentricity obtained using the proposed method leads to a more conservative design and reflects the differences in effective stiffness caused by variations in bearing deformations within the isolation layer. The proposed method has clear physical significance and produces reasonable numerical results.
隔震结构质量中心、结构形心、隔震层刚度中心分别记为CM(Center of Mass)、CI(Center of Inertia)、CS(Center of Stiffness)。建模过程中保持上部结构刚度中心与形心重合,同时令隔震层初始有效刚度中心与结构形心位置一致,仅引入上部结构质量偏心作为唯一偏心变量。本文将各楼层构件质量集中至楼板质心位置,通过调整楼层质心坐标实现不同大小的上部质量偏心,并严格保证各楼层总质量与基准隔震模型保持一致。通过对比集中质量模型与原分布质量模型的结构周期、层间位移角、构件内力及隔震支座位移响应,各计算结果吻合良好,验证了该质量集中建模方法的准确性与可靠性。通过沿x轴正向偏移各楼层质量中心,设置四级上部结构质量偏心工况,使初始偏心距e m 依次取为5%L、10%L、15%L、20%L,各偏心布置如图5所示。
YuWenzheng, TaoZhong, PanWen, et al. Comparative study on equivalent linearization calculation method in design of seismic isolated structure[J]. Journal of Building Structures, 2018, 39(1): 78-87.
ShiCheng, ZhangTongyi, RanTianran, et al. Study on response spectrum method based on equivalent linear model of isolated structures[J]. Building Structure, 2018, 48(17): 84-88.
TengXiaofei, TanPing, ZhouLinli, et al. Study on performance-based direct design method for seismic isolation structure[J]. Building Structure, 2019, 49(9): 71-76.
[7]
LiuT, ZordanT, BriseghellaB, et al. Evaluation of equivalent linearization analysis methods for seismically isolated buildings characterized by SDOF systems[J]. Engineering Structures, 2014, 59: 619-634.
LiangQiuhe. Research on calculation method of eccentricity of seismic isolation layer of isolation structure considering effective stiffness correction[D]. Guangzhou: Guangzhou University, 2020:1-31.
GeYicheng. Eccentricity of seismic isolation on structural torsional effects on the torsional effect of the structure[D]. Kunming: Kunming University of Science and Technology, 2024:1-45.
PanQinfeng, LinHuanzhou, XuLiying, et al. Torsion effect and control of foundation seismic isolation structure of plane irregular multi-layer frame structure[J]. Journal of Vibration Engineering, 2024, 37(12): 2021-2033.
[14]
KilarV, KorenD. Seismic behaviour of asymmetric base isolated structures with various distributions of isolators[J]. Engineering Structures, 2009, 31(4): 910-921.
[15]
PanT C, KellyJ M. Seismic response of torsionally coupled base isolated structures[J]. Earthquake Engineering & Structural Dynamics, 1983, 11(6): 749-770.
ZhaoJiandong, WangShuguang, LiuWeiqing. Analysis on the torsion parameters of L-shaped high-rise isolation buildings[J]. World Earthquake Engineering, 2010, 26(3): 74-79.
[18]
Tena-ColungaA. Seismic design of base-isolated buildings in Mexico. part 1: guidelines of a model code[J]. The Open Civil Engineering Journal, 2013, 7(1): 17-31.
[19]
ASCE/SEI 7-10 Minimum design loads for buildings and other structures [S].
[20]
International Conference of Building Officials. Uniform building code[M]. 19th ed. Whittier, CA: International Conference of Building Officials, 1997.
[21]
台内营字第0940087319号 建筑物耐震设计规范及解说 [S].
[22]
NoDocument. Tainei-Ying 0940087319 Seismic design code and commentary for buildings [S].
[23]
Eurocode 8 Design of structures for earthquake resistance: part 1:general rules, seismic actions and rules for buildings [S].
[24]
日本建築学会.免震構造設計指針[M]. 4th ed.東京:日本建築学会,2013.
[25]
MidorikawaM, OkawaI, IibaM, et al. Performance-based seismic design provisions newly introduced to the Building Standard Law of Japan[J]. Journal of Japan Association for Earthquake Engineering, 2004, 4(3): 162-173.
[26]
CECS 126: 2001 叠层橡胶支座隔震技术规程 [S].
[27]
CECS 126: 2001 Technical specification for seismic-isolation with laminated rubber bearing isolators [S].
[28]
GB/T 51408—2021 建筑隔震设计标准 [S].
[29]
GB/T 51408—2021 Standard for seismic isolation design of building [S].
[30]
GB 50011—2010 建筑抗震设计规范 [S].
[31]
GB 50011—2010 Code for seismic design of buildings [S].
[32]
DBJ/T 15-92—2021 高层建筑混凝土结构技术规程 [S]. DBJ/T 15-
[33]
92—2021 Technical specification for concrete structures of tall building [S].