When an underground utility tunnel crosses an active ground fissure site, the combined effects of the ground fissure interface and ground subsidence on its seismic performance must be considered. To investigate these effects on prefabricated prestressed utility tunnels, a quasi-static loading test was conducted to analyze the failure phenomena, deformation characteristics, and hysteretic behavior of the tunnel under transverse horizontal loading. Based on the test results, damage evaluation indices were determined, and seismic performance states were quantified. Numerical models were subsequently established for different ground fissure site conditions. The results indicate that the dynamic response of the utility tunnel is most pronounced at the ground fissure and gradually attenuates toward both sides. The hanging wall exhibits a greater response than the footwall, indicating a clear hanging-wall effect. Moreover, tunnel damage intensifies with increasing ground fissure subsidence. At a subsidence of 250 mm, the maximum inter-story drift ratio reached 1/93, which was 3.16 times that of a site without subsidence and 3.96 times that of an intact site. Using the incremental dynamic analysis method, 16 ground motion records were selected to develop a seismic vulnerability model for the utility tunnel. The failure probability under the coupled effects of different ground motion intensities and ground fissure subsidence levels was then evaluated. These findings provide a reference for the seismic design and disaster mitigation of prefabricated prestressed utility tunnels in active ground fissure sites.
LiuNina, PengJianbing, HanDongdong, et al. Mechanism of seismic damage of metro tunnels through active ground fissurs[J]. Chinese Journal of Rock Mechanics and Engineering, 2015, 34(7): 1384-1391.
HuangQiangbing, PengJianbing, WangFeiyong, et al. Issues and challenges in the development of urban underground space in adverse geological environment[J]. Earth Science Frontiers, 2019, 26(3): 85-94.
[5]
YanY F, HuangQ B, XieY L, et al. Failure analysis of urban open-cut utility tunnel under ground fissures environment in Xi'an, China[J]. Engineering Failure Analysis, 2021, 127: 105529.
[6]
DiemerD M, MillerM, PrattD L, et al. Seismic evaluation and improvement program for a major water system[C]//Lifeline Earthquake Engineering. New York: ASCE, 1995: 304-311.
WangHongyu, WangHao, GaoPinyi. On the research status of utility tunnel under earthquake load[J]. China New Technologies and New Products, 2016(24): 92.
YangXingkai, DengYahong, ChangJiang, et al. Dynamic response characteristics and seismic fortification of structures in ground fissure site[J]. China Earthquake Engineering Journal, 2022, 44(5): 1100-1109.
WangPing, LaiYouliang. Research on technical measures of Kunming Road comprehensive gallery crossing ground fissure site[J]. Construction & Design for Project, 2018(15): 151-154.
WangQiyao, LuGanggang, ZhangYaguo, et al. Study on the deformation and force characteristics of utility tunnel crossing ground fissure with the large angle[J]. Journal of Xi'an University of Architecture & Technology, 2019, 51(6): 825-832.
XuQiang, BaiChaoyu, PengJianbing, et al. Suitability analysis of assembly underground utility tunnel through active ground fissures[J]. Chinese Journal of Underground Space and Engineering, 2023, 19(2): 670-679, 690.
[17]
ZhangC, LiX, PangY K, et al. Mechanical response and deformation mechanism of the utility tunnel crossing earth fissure[J]. Structures, 2024, 64: 106587.
[18]
TsinidisG. Response characteristics of rectangular tunnels in soft soil subjected to transversal ground shaking[J]. Tunnelling and Underground Space Technology, 2017, 62: 1-22.
[19]
Saleh AsheghabadiM, Ali RahgozarM. Finite element seismic analysis of soil-tunnel interactions in clay soils[J]. Iranian Journal of Science and Technology, Transactions of Civil Engineering, 2019, 43(4): 835-849.
ShiXiaojun, ChenJun, LIJie. Shaking table test on underground utility tunnel[J]. Journal of Earthquake Engineering and Engineering Vibration, 2008, 28(6): 116-123.
JiCheng, QiaoQian, MengXianzhong, et al. Study on dynamic response of underground integrated pipe gallery trans-ground fissures under earthquake[J]. Building Construction, 2019, 41(11): 2069-2071, 2077.
[24]
WangK H, ChenY Y, HuangZ Y, et al. Analysis of influence characteristics of site conditions on seismic response of utility tunnel[J]. Buildings, 2024, 14(4): 1042.
FanZexu, YuanYong. Numerical study on the dynamic soil-structure interaction of utility tunnels in liquefiable sites[J]. China Earthquake Engineering Journal, 2026, 48(1): 114-122.
[27]
陈浩然. 黄土湿陷场地管廊的抗震性能研究[D]. 西安: 长安大学, 2024: 9-10.
[28]
ChenHaoran. Seismic performance study of utility tunnels in loess subsidence zones[D]. Xi'an: Chang'an University, 2024: 9-10.
[29]
GB 50011—2010 建筑抗震设计规范 [S].
[30]
GB 50011—2010 Code for seismic design of buildings [S].
WangYahui. Research on earthquake response laws and prevention measures of comprehensive pipe corridors across ground fractures[D]. Xi'an: Chang'an University, 2020: 19-20.
[33]
XuQ, BaiC Y, PengJ B, et al. Model test of prefabricated underground utility tunnel crossing active ground fissures[J]. Tunnelling and Underground Space Technology, 2023, 140: 105279.
YangZhao, LiYongzhi, YangRui. Analysis on cracks of cast-in-place utility tunnel induced by uneven settlement: a case study of utility tunnel of Fuzhou southeast freeway[J]. Tunnel Construction, 2021, 41(12): 2098-2105.
[36]
GB 50010—2010 混凝土结构设计规范 [S].
[37]
GB 50010—2010 Code for the design of concrete structures [S].
ShaoXiaozhou, FanWenxin, WangYafei, et al. Experimental investigation on Mooney-Rivlin modified model of metal rubber[J]. Packaging Engineering, 2021, 42(9): 135-140.
BaiChaoyu. Mechanism study of deformation and failure on prefabricated underground utility tunnel crossing active ground fissures[D]. Xi'an: Chang'an University, 2023: 43-44.
LiJinqiang, ZhongZilan, ShenJiaxu, et al. Longitudinal seismic fragility analysis of utility tunnel structures based on IDA method[J]. Chinese Journal of Geotechnical Engineering, 2024, 46(8): 1622-1631.
XiongZhongming, LiRunpeng, XiongJunlong, et al. Seismic performance evaluation of subway station structure in ground fissure site under coupling effects of dislocation and seismic load[J]. China Civil Engineering Journal, 2025, 58(10): 74-87.