To make the finite element model of closed section pipe components more in line with the actual situation, the buckling mode is often introduced into the model as the initial imperfection of the structure, so as to induce a finite element model with a deformation mode consistent with the actual working conditions. However, the finite element buckling analysis results show that the buckling modes after adding initial defects often fail to meet the requirements of the actual crushing mode. In this paper, a group of quadrilateral closed-section pipe fittings are tested under axial compression, and the actual deformation mode of closed-section pipe fittings is obtained, and a solution method of coefficient superposition is proposed.Through the linear superposition of buckling modes, the modal characteristics consistent with the actual deformation modes are obtained.This method is compared and verified with the test results of relevant literatures.The results show that the calculation process of this method is simpler, and the obtained index parameters are closer to the actual situation, and the extension is stronger.
XUF X, ZHANGX, ZHANGH. A review on functionally graded structures and materials for energy absorption[J]. Engineering Structures, 2018, 171: 309-325.
[2]
CHENW G, WIERZBICKIT. Relative merits of single-cell, multi-cell and foam-filled thin-walled structures in energy absorption[J]. Thin-Walled Structures, 2001, 39(4): 287-306.
[3]
WIERZBICKIT, BHATS U, ABRAMOWICZW, et al. Alexander revisited:a two folding elements model of progressive crushing of tubes[J]. International Journal of Solids and Structures, 1992, 29(24): 3269-3288.
[4]
ABRAMOWICZW, WIERZBICKIT. Axial crushing of multicorner sheet metal columns[J]. Journal of Applied Mechanics, 1989, 56(1): 113-120.
[5]
ABRAMOWICZW, JONESN. Dynamic axial crushing of square tubes[J]. International Journal of Impact Engineering, 1984, 2(2): 179-208.
[6]
WIERZBICKIT, ABRAMOWICZW. On the crushing mechanics of thin-walled structures[J]. Journal of Applied Mechanics, 1983, 50(4a): 727-734.
[7]
WIERZBICKIT. Crushing analysis of metal honeycombs[J]. International Journal of Impact Engineering, 1983, 1(2): 157-174.
[8]
MCFARLANDR K. Hexagonal cell structures under post-buckling axial load[J]. AIAA Journal, 1963, 1(6): 1380-1385.
[9]
FALKOWICZK. Stability and failure of thin-walled composite plate elements with asymmetric configurations[J]. Materials, 2024, 17(9): 1943.
[10]
CHENY, SHIJ Y, LUC H, et al. Hierarchical clustering-based collapse mode identification and design optimization of energy-dissipation braces inspired by the triangular resch pattern[J]. Journal of Structural Engineering, 2024, 150(5): 04024037.
[11]
MAHDYW M, WANGL J, LIUF R, et al. The competition between buckling and stress failure of degraded composite cylindrical shell under combined axial compression and external pressure loads[J]. Thin-Walled Structures, 2024, 199: 111731.
[12]
HEZ Q, PENGS Q, ZHOUX H, et al. Design recommendation of cold-formed steel built-up sections under concentric and eccentric compression[J]. Journal of Constructional Steel Research, 2024, 212: 108255.
[13]
ZHANGZ B, LIUQ, FUJ, et al. Parametric study on the crashworthiness of the Al/CFRP/GFRP hybrid tubes under quasi-static crushing[J]. Thin-Walled Structures, 2023, 192: 111156.
[14]
SEE T, MCCONNELR E. Large displacement elastic buckling of space structures[J]. Journal of Structural Engineering, 1986, 112(5): 1052-1069.
[15]
CHENX, SHENS Z. Complete load-deflection response and initial imperfection analysis of single-layer lattice dome[J]. International Journal of Space Structures, 1993, 8(4): 271-278.
EUROPEANSTANDARD NORMEEUROPEENNE EUROPAISCHE NORM. Eurocode 3: Design of steel structures:Part 1-6: Strength and stability of shell structures [S/OL]. (1993:01-06)[2025-02-24].
[21]
ALAVINIA A, HADDAD HAMEDANIJ. Comparative analysis of energy absorption and deformations of thin walled tubes with various section geometries[J]. Thin-Walled Structures, 2010, 48(12): 946-954.
[22]
ZHANGX, ZHANGH. Experimental and numerical investigation on crush resistance of polygonal columns and angle elements[J]. Thin-Walled Structures, 2012, 57: 25-36.