In order to calibrate the dynamic sensitivity of piezoelectric force sensors under the impact force calibration device, the drop hammer impact force model based on free-falling bodies and the horizontal mass block impact collision model based on air-bearing suspension support was first introduced. Then, through 4th order Butterworth low-pass filtering, the filtering smoothness of acceleration signal waveform was studied, and the filtering effects of different cut-off frequencies were compared. Finally, a comparative experiment was conducted on the measurement of acceleration using a laser vibrometer and a standard accelerometer to investigate the impact of the absolute acceleration measurement method and comparative measurement method on the accuracy of dynamic sensitivity calibration of force sensors. The experimental results indicate that the acceleration measurement of the laser vibration meter must be achieved through differential demodulation, and a 4-order Butterworth low-pass filter with an appropriate upper cut-off frequency should be selected for filtering and smoothing processing; The dynamic force accuracy reproduced by the absolute laser interference method is 2%, and the dynamic force accuracy reproduced by the accelerometer comparison method is 4%; The sensitivity fluctuation of laser interference absolute method calibration is smaller than that of accelerometer comparison method calibration.
KUMMER.Investigation of the comparison method for the dynamic calibration of force transducer[J]. Measurement,1998, 23: 239-245.
[2]
SAHOON, SURYAVAMSHIK, REDDYK P J . et al .Dynamic force balances for short-duration hypersonic testing[J]. Fluids: Facilities Experiments, 2005, 38(5): 606-614.
[3]
FUJ Y. Measurement of steep impulse response of a forcetransducer[J]. Measurement Science and Technology, 2003, 14: 65-69.
ZHANGYifei, KONGDeren, SHIYucheng. Research on influencing factors of step pressure rise time of quick-opening valve device[J]. Journal of Test and Measurement Technology, 2021, 35(2): 107-113. (in Chinese)
JIANGWensong. LUO Zai. WANG Zhongyu,et al. Impact force calibration method based on load reconstruction[J]. Journal of Vibration and Shock, 2020, 39(13): 22-26. (in Chinese)
SHANGYiqi, LIShanming, CAOYiqing, et al. Design and data verification of lifting and righting mechanism of impulse force generator [J]. Metrology & Measurement Technology, 2017, 37(6): 35-39. (in Chinese)
SHANGYiqi, HEXuan, LIShanming, et al. The designs and data verification of hammer mass block of impulse force generator[J]. Metrology & Measurement Technology, 2018, 38(2): 26-29. (in Chinese)
SHIXiangqing, XUChundong, KONGDeren, et al. Experimental study on dynamic calibration of pressure sensor based on pre-pressure water shock tube[J]. Journal of Test and Measurement Technology, 2020, 34(5): 401-406. (in Chinese)
GUTingwei, KONGDeren, SHANGFei, et al. Research on an absolute calibration method of monitoringpressure by force sensor based on drop-weight device[J]. Chinese Journal of Scientific Instrument, 2017, 38(3): 750-756. (in Chinese)
GUBaodong, CHENHuaihai, SHENFan, et al. Research on dynamic calibration of force sensor and its precision analysis[J]. Journal of Vibration and Shock, 2005, 24(2): 95-98. (in Chinese)
LIANGZhiguo.A discussion on differential processing and peak filtering in impulse acceleration calibration[J]. Journal of Vibration and Shock, 2017, 36(22): 73-79. (in Chinese)
MENGFeng, ZHANGYue, LITao, et al. Research of calibration machine of impulse type dynamic force[J]. Ship Engineering, 2012, 34(S2): 77-79. (in Chinese)
LUXiaoben, ZHAIQiongjie, TUChun, et al. Calibration method of piezoelectric dynamic force sensor[J]. Journal of Vibration and Shock, 2021, 40(5): 261-265. (in Chinese)
[29]
KOBUSCHM, KLAUSL, BRUNST. Investigations for the model-based dynamic calibration of force transducers by using shock forces[C]//IMEKO TC22 Conference on Vibration Measurement, 2014: 1-4.