输电线路钢管-插板节点面外抗弯性能试验研究
陈志辉 , 付诗禧 , 黄雄辉 , 徐彬 , 冯衡 , 刘红军
建筑钢结构进展 ›› 2025, Vol. 27 ›› Issue (09) : 52 -63.
输电线路钢管-插板节点面外抗弯性能试验研究
Experimental Study on Out-of-Plane Flexural Behavior of Steel Tube-Plug Joints for Transmission Lines
为研究特高压输电钢管塔中C型插板连接典型节点的面外抗弯性能,文中对10个足尺K形节点进行了面外抗弯承载力试验,研究了插板厚度、节点板厚度与螺栓个数对节点面外抗弯性能的影响。在此基础上,还建立了节点的有限元有效模型并对其进行了参数分析,考察了插板与节点板厚度、螺栓个数与螺栓直径、主管径厚比、斜管径厚比以及钢材强度对节点面外抗弯刚度的影响,提出了此类节点面外抗弯刚度的建议计算公式。研究结果表明:在所有试验工况中,插板与节点板厚度的变化,使节点初始转动刚度较基准工况的最大增幅达40.28%;螺栓个数的变化使该刚度的最大增幅为34.30%;钢材强度对节点初始转动刚度的影响趋势为先线性增加后趋于平缓,主管径厚比对节点初始转动刚度的影响甚微,而斜管径厚比与节点板宽厚比对节点面外抗弯刚度的影响较为显著;基于试验和有限元模拟结果提出的节点面外抗弯刚度计算公式具有较好的适用性,可为实际工程提供参考。
In order to study the out-of-plane flexural behavior performance of typical joints of C-type gusset plate connection of UHV transmission steel pipe tower, 10 full-scale K-type joints were tested in this paper. The effects of gusset plate thickness, joint plate thickness and bolt number on the out-of-plane flexural behavior performance of joints were studied. On this basis, the finite element model of the joint was established and the parametric analysis was carried out. The effects of the thickness of the gusset plate and the joint plate, the number and the diameter of bolts, the diameter-thickness ratio of the main pipe, the diameter-thickness ratio of the inclined pipe and the steel strength on the out-of-plane flexural behavior of the joint were investigated. The formula for calculating the out-of-plane flexural behavior of such joints was proposed. The results show that: In all test conditions, the maximum increase in the initial rotational stiffness of the joints caused by the thickness of the gusset plate and the joint plate is 40.28%, and the maximum increase in the initial rotational stiffness of the joints caused by the number of bolts is 34.30%. The influence of steel strength on the initial rotational stiffness of the joint increases linearly first and then tends to be gentle. The diameter-thickness ratio of the main pipe has little effect on the initial rotational stiffness of the joint, while the diameter-thickness ratio of the inclined pipe and the width-thickness ratio of the joint plate have a significant effect on the out-of-plane flexural behavior of the joint. Based on the experimental and finite element simulation results, the calculation formula of out-of-plane flexural behavior of joints has good applicability, which can provide reference for practical engineering.
| [1] |
段军,张黎军,孙传琦,大跨越钢管塔内外法兰节点偏压承载力特性试验研究[J].钢结构,2018,33(4):7-12.DOI:10.13206/j.gjg201804002. |
| [2] |
DUAN Jun,ZHANG Lijun,SUN Chuanqi,et al.Experimental research on bearing capacity characteristics of inner-outer double layered flange of long-span steel pipe tower under eccentric compression[J].Steel Construction,2018,33(4):7-12.DOI:10.13206/j.gjg201804002.(in Chinese) |
| [3] |
刘春城,李国强,樊晓玲,大跨越钢管塔K型节点滞回性能分析[J].东北电力大学学报,2017,37(6):79-85.DOI:10.19718/j.issn.1005-2992.2017.06.013. |
| [4] |
LIU Chuncheng,LI Guoqiang,FAN Xiaoling,et al.The analyses on hysteretic performance of K-type node in large span steel tubular tower[J].Journal of Northeast Electric Power University,2017,37(6):79-85.DOI:10.19718/j.issn.1005-2992.2017.06.013.(in Chinese) |
| [5] |
杨卫忠,王茜.钢结构半刚性连接弯矩-转角关系模型研究[J].郑州大学学报(理学版),2015,47(1):115-118,124.DOI:10.3969/j.issn.1671-6841.2015.01.025. |
| [6] |
YANG Weizhong,WANG Qian.Constitutive equation model for semi-rigid connection of steel structure[J].Journal of Zhengzhou University (Natural Science Edition),2015,47(1):115-118,124.DOI:10.3969/j.issn.1671-6841.2015.01.025.(in Chinese) |
| [7] |
GIRÃO COELHO A M,BIJLAARD F S K,SIMÕES DA SILVA L.Experimental assessment of the ductility of extended end plate connections[J].Engineering Structures,2004,26(9):1185-1206.DOI:10.1016/j.engstruct.2000.09.001. |
| [8] |
苏志钢,刘海锋,朱彬荣,钢管输电塔K节点承载力算法的优化研究[J].浙江工业大学学报,2021,49(4):397-402.DOI:10.3969/j.issn.1006-4303.2021.04.006. |
| [9] |
SU Zhigang,LIU Haifeng,ZHU Binrong,et al.Optimization of K-joint joint bearing capacity algorithm for steel tube transmission tower[J].Journal of Zhejiang University of Technology,2021,49(4):397-402.DOI:10.3969/j.issn.1006-4303.2021.04.006.(in Chinese) |
| [10] |
李晓露,吕宝华,陈泽群,输电钢管塔环板节点极限承载力的理论研究[J].应用力学学报,2013,30(1):86-91,149. |
| [11] |
LI Xiaolu,LYU Baohua,CHEN Zequn,et al.Theoretical research of ultimate bearing capacity of steel tubular tranmission tower's joints with annular plane[J].Chinese Journal of Applied Mechanics,2013,30(1):86-91,149.(in Chinese) |
| [12] |
曹正罡,王佳龙,王志成,输电塔K型纵板加劲相贯节点抗压承载力研究[J].哈尔滨工业大学学报,2020,52(10):28-35.DOI:10.11918/201905052. |
| [13] |
CAO Zhenggang,WANG Jialong,WANG Zhicheng,et al.Study on compressive bearing capacity of K-type longitudinal plate stiffened tubular joints of transmission towers[J].Journal of Harbin Institute of Technology,2020,52(10):28-35.DOI:10.11918/201905052.(in Chinese) |
| [14] |
吴海洋,包永忠,郭念.输电铁塔钢管构件轴压承载力研究[J].电力科学与工程,2014,30(11):47-51,56.DOI:10.3969/j.issn.1672-0792.2014.11.010. |
| [15] |
WU Haiyang,BAO Yongzhong,GUO Nian.Research on the axial compressive bearing capacity of steel-tube element of power transmission tower[J].Electric Power Science and Engineering,2014,30(11):47-51,56.DOI:10.3969/j.issn.1672-0792.2014. 11.010.(in Chinese) |
| [16] |
李茂华,邢海军,胡晓光,输电线路钢管塔小角度K形节点承载力研究[J].建筑结构,2013,43(5):48-53.DOI:10.19701/j.jzjg.2013.05.010. |
| [17] |
LI Maohua,XING Haijun,HU Xiaoguang,et al.Research on load-carrying capacity of smaller angle K-joints for power transmission steel tubular tower[J].Building Structure,2013,43(5):48-53.DOI:10.19701/j.jzjg.2013.05.010.(in Chinese) |
| [18] |
焦安亮,李正良,刘红军,特高压输电塔半刚性连接K形节点受力性能研究[J].建筑结构学报,2014,35(7):53-60.DOI:10.14006/j.jzjgxb.2014.07.007. |
| [19] |
JIAO Anliang,LI Zhengliang,LIU Hongjun,et al.Study on ultimate strength of semi-rigid K-type joints in UHV transmission tower[J].Journal of Building Structures,2014,35(7):53-60.DOI:10.14006/j.jzjgxb.2014.07.007.(in Chinese) |
| [20] |
赵楠.特高压输电塔半刚性连接节点受力性能及结构非线性分析研究[D].重庆:重庆大学,2014. |
| [21] |
ZHAO Nan.Study on load-bearing performances of semi-rigid joints and structure nonlinear analysis of UHV transmission tower[D].Chongqing:Chongqing University,2014.(in Chinese). |
| [22] |
丁洁民,沈祖炎.一种半刚性节点的实用计算模型[J].工业建筑,1992,22(11):29-32. |
| [23] |
DING Jiemin,SHEN Zuyan.A practical calculating model for semi-rigid connections[J].Industrial Construction,1992,22(11):29-32.(in Chinese) |
| [24] |
熊川,郭耀杰,李旋.梁柱齐平端板半刚性节点力学性能研究[J].中国科技论文,2019,14(10):1066-1071.DOI:10. 3969/j.issn.2095-2783.2019.10.005. |
| [25] |
XIONG Chuan,GUO Yaojie,LI Xuan.Research on mechanical properties of flush end plate semi-rigid beam-column joints[J].China Sciencepaper,2019,14(10):1066-1071.DOI:10.3969/j.issn.2095-2783.2019.10.005.(in Chinese) |
| [26] |
安利强,朱登杰,武文玲,节点半刚性对特高压钢管塔静力特性的影响[J].应用力学学报,2015,32(6):1019-1024,1105.DOI:10.11776/cjam.32.06.B140. |
| [27] |
AN Liqiang,ZHU Dengjie,WU Wenling,et al.Influence of joint semi-rigidity on the static characteristic for UHV transmission steel tubular tower[J].Chinese Journal of Applied Mechanics,2015,32(6):1019-1024,1105.DOI:10.11776/cjam.32.06.B140.(in Chinese) |
| [28] |
国家市场监督管理总局,国家标准化管理委员会.钢及钢产品 力学性能试验取样位置及试样制备:GB/T 2975—2018[S].北京:中国标准出版社,2018. |
| [29] |
State Administration for Market Regulation,National Standardization Administration.Steel and Steel Products—Location and Preparation of Samples and Test Pieces for Mechanical Testing:GB/T 2975—2018[S].Beijing:Standards Press of China,2018.(in Chinese) |
| [30] |
国家市场监督管理总局,国家标准化管理委员会.金属材料 拉伸试验 第1部分:室温试验方法:GB/T 228.1—2021[S].北京:中国标准出版社,2021. |
| [31] |
State Administration for Market Regulation,National Standardization Administration.Metallic Materials—Tensile Testing:Part 1:Method of Test at Room Temperature:GB/T 228.1—2021[S].Beijing:Standards Press of China,2021.(in Chinese) |
中国南方电网有限责任公司2023年第一批定向科技项目(CGYKJXM20220236)
/
| 〈 |
|
〉 |