End-stage renal disease (ESRD), also known as kidney failure, refers to the final stage of chronic kidney disease (CKD), where the kidneys lose 85%-90% function and can no longer sustain life in the long term
[1-2]. Kidney replacement therapy (KRT) is the primary treatment for ESRD aimed at alleviating symptoms and sustaining life, including hemodialysis, peritoneal dialysis, and kidney transplantation
[3]. However, due to continuous dialysis, taking immunosuppressants, and costly medical expenses, patients receiving KRT still experience substantial symptoms and live with poor health-related quality of life (HRQoL)
[4-5]. Fatigue is the most common symptom among dialysis patients (70%), and over half of kidney transplant recipients report bone or joint pain (55%), constipation (53%), and muscle weakness (56%)
[6]. These symptoms are associated with increased complications and mortality rates, yet they are not routinely assessed in clinical care
[7-8].
Patient-reported outcome measures (PROMs) collect experiences and feelings directly reported from patients, without any interpretation from others, which are garnering increasing attention from researchers and healthcare professionals
[9-11]. Derived from item response theory (IRT), the National Institutes of Health developed the Patient-Reported Outcomes Measurement Information System (PROMIS) to assess health-related outcomes in both healthy and diseased populations
[12]. The scores of measures in PROMIS can be converted into standardized T-scores
[13], allowing for comparability of health status across languages, conditions, and diseases. Despite the advantage of comparability, instruments in PROMIS need to be assured of good psychometric properties before being applied to health systems.
PROMIS profiles consist of 7 PROMIS short forms and one item measuring pain intensity, and they include 3 profile versions: PROMIS-29 (4 items for each short form), PROMIS-43 (6 items for each short form), and PROMIS-57 (8 items for each short form). The 7 short forms measure 7 health-related core domains, including physical function, anxiety, depression, fatigue, sleep disturbance, ability to participate in social roles and activities, and pain interference
[14]. The shorter profiles are nested within the longer profiles. The CKD working group of the International Consortium of Health Outcomes Measurement (ICHOM) has recommended PROMIS-29 to evaluate HRQoL and symptoms (e.g., pain, fatigue, depression) of CKD
[15]. As a precise, brief, and comparable tool, PROMIS-29 has been translated into various languages and validated among different populations
[16-18]. Through rigorous translation and cross-cultural adaptation process, Cai, et al
[19] have formed the Chinese version of PROMIS-29 (nested within PROMIS-57) and validated it in patients with breast cancer. However, the Chinese version has not yet been validated in the field of nephrology. Given the cultural and linguistic disparities, it is imperative to evaluate the psychometric properties of the Chinese version of PROMIS-29 before its implementation in nephrological clinical practice.
Patients undergoing KRT require regular assessment of symptoms and HRQoL to evaluate and improve treatment outcomes, and PROMs offer a valuable means to capture patient perspectives. Therefore, our study aims to evaluate the reliability and validity of the PROMIS-29 in adult patients on KRT in China. This validation would facilitate the integration of PROMIS-29 into nephrology practice and enhance HRQoL and symptom assessment in dialysis and transplant patients.
1 Materials and methods
1.1 Ehtics statements
1.2 Study design and sample
This was a cross-sectional study evaluating the Chinese version of PROMIS-29 in a sample of adult patients receiving KRT. Patients aged 18 years or older, who had undergone dialysis or kidney transplantation for more than 3 months, were recruited from November 2023 to January 2024 at a comprehensive hospital in Hunan, China. Patients in the acute phase of illness, with cognitive impairments preventing them from completing the questions on their own, or lacking basic reading ability were excluded. The sample size was determined with reference to the Consensus-Based Standards for the Selection of Health Measurement Instruments (COSMIN) guideline for study design
[20]. Structural validity requires at least 5 times, the number of items and IRT-based analyses require at least 150 observations per group. Based on the projected analyses in this study, a minimum sample of 450 cases was considered adequate.
1.3 Data collection
Questionnaires including socio-demographic and clinical data, the PROMIS-29, and legacy measurements were completed on an online survey system (Wen Juan Xing), accessible conveniently by scanning a quick response (QR) code. Trained researchers and nurses administered the QR code in the WeChat groups for patients, transplant wards, nephrology wards, and hemodialysis centers. To ensure the quality of the questionnaire, all questions must be completed before submission, resulting in no missing data, and each WeChat account can only submit the questionnaire once. Additionally, questionnaires with a response time of less than 350 s or those that failed the attention-check item were excluded from the analysis. Two authors examined the data and determined the final data to be included in the analysis based on inclusion and exclusion criteria.
1.4 Measures
1.4.1 Sociodemographic and clinical characteristics
Sociodemographic characteristics included self-reported age, gender, body mass index (BMI), marital status, years of education, working status, and household monthly income. Clinical characteristics included self-reported primary kidney disease, time on dialysis or time since transplant, and comorbidities. Comorbidities were assessed using a multiple-choice item, allowing participants to select all conditions that applied.
1.4.2 PROMIS-29
PROMIS-29 profile v2.1 comprises 29 items assessing 7 health-related domains (physical function, anxiety, depression, fatigue, sleep disturbance, ability to participate in social roles and activities, and pain interference) and a item pain intensity
[21]. Except for the single pain intensity item utilizing a numeric rating scale from 0 to 10, each of the other 7 domains contains 4 items rated on a 5-point Likert scale (score 1-5)
[22]. Raw scores for each domain are converted into T-scores using HealthMeasures Scoring Service, where a higher score represents a greater degree of the trait under assessment. T-scores are standardized scores with a mean of 50 and a standard deviation of 10, reflecting the respondent’s standing relative to the general population, and therefore do not have a fixed absolute range
[13].
1.4.3 Legacy measures
We chose validated and brief instruments to compare with PROMIS-29. The 12-Item Short Form Health Survey (SF-12) is a widely used questionnaire that consists of 8 dimensions: Physical functioning (PF), role physical (RP), bodily pain (BP), general health (GH), vitality (VT), social functioning (SF), role-emotional (RE), and mental health (MH)
[23]. According to the reference formula, the responses of the first 4 dimensions can be aggregated to calculate the physical component summary (PCS), while the scores from the last 4 dimensions can be calculated to determine the mental component summary (MCS)
[24]. The score of each dimension and summary ranges from 0 to 100, with a higher score indicating better HRQoL. The Chinese version of SF-12 demonstrated good convergent and discriminant validity, along with good internal consistency (Cronbach’s α=0.910)
[25].
The Patient Health Questionnaire (PHQ-9) was developed based on the 9 symptoms outlined for diagnosing depression in the
Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV) and contains 9 items. This scale inquiries about the frequency of being bothered over the past 2 weeks, with each item scored on a scale from 0 to 3 (0 for “not at all” and 3 for “nearly every day”)
[26]. The total score ranges from 0 to 27, with higher scores indicating higher levels of depression. The Chinese version of PHQ-9 was validated with a Cronbach’s α of 0.86 and a test-retest reliability of 0.86
[27].
The Generalized Anxiety Disorder 7-Item Scale (GAD-7) was derived from the diagnostic criteria for generalized anxiety disorder (GAD) in the DSM-IV, and it is extensively employed for the assessment and screening of GAD
[28]. It consists of 7 questions asking about the frequency of anxiety symptoms over the past 2 weeks. As with the PHQ-9, each entry is rated on a scale of 0-3, with a total score of 0-21. The Chinese version showed good internal consistency, with a Cronbach’s α of 0.928
[29].
1.5 Statistical analysis
1.5.1 Descriptive analysis
Descriptive analysis was performed to illustrate sample characteristics and PROMIS-29 scores. Mean± standard deviations and median (P25, P75) were analyzed for continuous variables, while frequencies and percentages were computed for categorical variables. We used the χ2 test, F test and the Kruskal-Wallis H test to compare the differences among patients undergoing hemodialysis, peritoneal dialysis, and kidney transplant recipients.
1.5.2 Reliability and floor/ceiling effects
Internal consistency was measured with Cronbach’s α. It was regarded as excellent, good, and acceptable when coefficient α is ≥0.90, 0.80-0.89, and 0.70-0.79, respectively
[30]. We assessed floor and ceiling effects for each domain and the single pain intensity item by calculating the proportions of participants scoring at the lowest (floor) and highest (ceiling) levels. A threshold of exceeding 30% was considered to indicate significant floor or ceiling effects
[31].
1.5.3 Construct and criterion validity
Confirmatory factor analysis (CFA) using the maximum likelihood estimation method was employed to assess the one-factor structure of each domain of the PROMIS-29, confirming its unidimensionality. Based on the results of the CFA of each single domain, the 7-factor structure was examined. The model fit indices were comparative fit index (CFI), Tucker-Lewis index (TLI), root mean square error of approximation (RMSEA), and standardized root mean square residual (SRMR). The model fit is considered adequate when both CFI and TLI exceed 0.95, RMSEA is below 0.06, and SRMR is less than 0.08
[32].
Convergent and discriminant validity was measured by calculating average variance extracted (AVE) and composite reliability (CR) of each construct. Good convergent validity was indicated if the AVE value for each construct was >0.50 and the CR value was >0.70
[33]. The square root of AVE for a particular dimension being greater than the correlation coefficients between this dimension and others indicated good discriminant validity
[34]. Criterion validity was examined by analyzing Spearman’s correlations between PROMIS-29 domains and similar constructs in legacy measures. The values above 0.50 were considered acceptable criterion validity
[18].
1.5.4 Measurement invariance
Measurement invariance is an essential assumption for construct validity, as it ensures that the measurement assesses the same construct consistently across different groups or conditions
[35]. In our study, measurement invariance was determined by analyzing whether differential item functioning (DIF) existed using the graded response model (GRM), which assumes that item responses are conditionally independent and residual correlations are not allowed. Using the “lordif” package in R
[36], DIF was tested by ordinal Logistic regression method with respect to age (younger group ≤49 years, or older group >49 years), gender (male or female), years of education (≤12 years, or >12 years), and treatment (hemodialysis, peritoneal dialysis, or kidney transplant). The age group was divided according to the median. Monte Carlo simulations (S=1 000 replications) were employed to construct the empirical null distribution of McFadden’s pseudo
R2 change under the null hypothesis of no DIF, and the 95th percentile of this distribution was used as the item-specific critical value to address multiple comparisons
[36]. As suggested by PROMIS Health Organization, McFadden’s pseudo
R2 with a change of ≥0.02
[37] was employed as the threshold to signify significant DIF.
1.5.5 IRT analysis
To visually investigate the difficulty, discrimination, and information value of the measurement, item characteristic curves (ICCs) and test information curves (TICs) were plotted based on the GRM model fit. ICCs provide the probability of a particular response to an item given different levels of latent trait (θ)
[38]. TICs depict the distribution of test information across various ability levels, enabling the assessment of the test’s measurement precision and accuracy
[39]. In our study, we employed the “mirt” package in R to perform analyses of ICCs and TICs
[40].
Except for the CFA conducted using AMOS version 26.0, and the DIF, ICCs, and TICs measured by R version 4.3.3, all other statistical analyses were performed in SPSS version 27.0. The two-tailed P value <0.05 was considered statistically significant.
2 Results
2.1 Participant characteristics
A total of 559 adult patients with KRT were invited and assessed for eligibility. Fifty-nine participants were excluded based on the inclusion and exclusion criteria, resulting in a final sample of 500 patients for analysis. Among the cohort, the age was (48.76±12.59) years, 56.0% of them were male, and the majority (77.0%) were married. Most participants had undergone dialysis or received transplants for a period spanning 1 to 5 years (52.3% for patients on hemodialysis, 55.6% for patients on peritoneal dialysis, and 45.9% for kidney transplant recipients). Excluding unclear cases of primary kidney disease, the top 3 causes were glomerulonephritis/sclerosis (23.2%), hypertension/renal vascular disease (20.0%), and diabetes mellitus (10.4%). Statistically significant differences were observed in age, gender, years of education, working status, household monthly income, primary kidney disease, and partial comorbidities among patients receiving different treatments. In health-related PROMIS-29, kidney transplant recipients got higher scores in positive domains and lower scores in negative domains than patients on dialysis. The results of sample characteristics are presented in
Table 1.
2.2 Reliability, and floor/ceiling effects
The PROMIS-29 T-scores and pain intensity raw score are displayed in
Table 1. Physical function domain obtained the lowest median T-score at 48.6 (42.9, 57.0) and anxiety domain got the highest at 56.0 (40.3, 63.5). Internal consistency was sufficient for all domains, with the Cronbach’s α ranging from 0.75 to 0.96 (
Table 2). According to the criteria of ≥30%, a notable ceiling effect was observed in physical function domain (42.2%), whereas pain interference domain exhibited a substantial floor effect (37.4%;
Table 2).
2.3 Structural validity
CFA was individually conducted across the 7 domains of PROMIS-29, and the results demonstrated satisfactory model fit for all subscales. As shown in
Table 3, the CFI and TLI values for all domains were >0.95, RMSEA values ranged between 0.000 to 0.069, and all SRMR values were <0.08. Therefore, the unidimensional structure of the subscales was confirmed. Moreover, the CFA of the whole PROMIS-29 also revealed a favorable model fit (CFI=0.975, TLI=0.971, RMSEA=0.046, SRMR=0.056), confirming the 7-factor structure. Except for item Sleep116 within the sleep disturbance domain (factor loading=0.17), factor loadings for all other items were above 0.5, ranging from 0.70 to 0.97.
2.4 Convergent validity and discriminant validity
In our study, we analyzed AVE, CR, and correlation coefficients through the AMOS plugin developed by Gaskin, et al
[41]. Good convergent validity was evidenced, having AVE values that fall within the range of 0.506 to 0.863 and CR values of 0.778 to 0.962 (
Table 4). Additionally, the square root of AVE value for each domain displayed in the diagonal were all greater than the correlation coefficients with other dimensions in its row and column, signaling robust discriminant validity (
Table 4).
2.5 Criterion validity
Correlations between PROMIS-29 subscales and the corresponding structure of legacy measurements were presented in
Table 5, showing acceptable criterion validity (
r>0.50). Strong correlations were found between the anxiety domain and GAD-7 (
r=0.71, 95%
CI 0.66 to 0.75), as well as between the depression domain and PHQ-9 (
r=0.73, 95%
CI 0.68 to 0.77).
2.6 Measurement invariance
DIF was detected only for item PFA21 (“Are you able to go up and down stairs at a normal pace”) across education and treatment groups. No DIF was detected for remaining items across different age, gender, years of education, and treatment groups. For all items except PFA21, the changes in McFadden’s pseudo
R2 values were less than 0.02, indicating negligible DIF. Overall, these findings support the measurement invariance of the instrument across demographic and clinical subgroups. Detailed data is presented in Supplementary
Table 1 (
https://doi.org/10.57760/sciencedb.xbyxb.00187).
2.7 Item characteristic and test information
As illustrated in
Figure 1, the ICCs of most items exhibited monotonicity in their first and last curves, while the remaining 3 curves followed a normal distribution, which was close to the ideal form. However, the curves of item Sleep116 showed a flat pattern and crossover, indicating poor discrimination of individuals with different abilities.
The results of TIC for each domain are depicted in
Figure 2. The sleep disturbance provided the lowest information, with maximum information reaching about 10. This was followed by the fatigue and sociability domains, with a maximum of about 20. The pain interference domain demonstrated a maximum information content exceeding 60. However, its curve displayed relatively apparent spikes, indicating the test’s high precision in measuring at specific levels of ability.
3 Discussion
This was the first study to evaluate the psychometric performance of the Chinese version of PROMIS-29 in patients undergoing KRT. Our findings indicated sufficient internal consistency, well-performed structural validity, excellent convergent and discriminant validity, acceptable criterion validity, and reliable measurement equivalence of each subscale. Notably, a significant ceiling effect was observed in the physical function domain, while the pain interference domain exhibited a prominent floor effect. Additionally, the analysis of ICCs and TICs provided further valuable insights into the measurement properties.
The mean T-scores of PROMIS-29 revealed that the anxiety and depression were higher compared with the US general population, highlighting the importance of MH care. Among different types of KRT, patients undergoing hemodialysis exhibited the most severe symptoms, demonstrating the lowest physical function score, the highest levels of fatigue, anxiety, depression, and pain intensity and interference. According to a survey conducted in three major cities in China, there were still 20.2% of patients receiving hemodialysis twice a week, indicating inadequate dialysis frequency which could aggravate related symptoms
[42-43]. Patients with longer interdialytic interval manifested higher symptoms frequency and severity
[44]. Additionally, the prolonged and frequent hospital visits, rapid fluctuations in osmolality and body fluid levels, as well as the necessity of punctures and tube placement associated with hemodialysis treatment would also contribute to the heightened symptom levels of patients on hemodialysis
[4, 45]. In contrast, kidney transplant recipients had the best health-related scores, which were similar to the US general population. Kidney transplantation provides a functional kidney and offers patients the opportunity for a more normal lifestyle, leading to reduced symptom burden.
Overall, all subscales of PROMIS-29 demonstrated acceptable internal consistency, with Cronbach’s α ranging from 0.75 to 0.96. Among the 7 domains, the sleep disturbance domain was the only one with a Cronbach’s α lower than 0.90, obtaining a value of 0.75, which was consistent with other language versions
[17, 46]. This may be attributed to the difficulty in understanding the item Sleep116 (my sleep was refreshing), which responders reflected was hard to understand and answer. This item seeks to understand whether participants feel comfortable and energized after sleeping over the past 7 days, emphasizing the effects of sleep. However, it might be misinterpreted as assessing the refreshing aspect of the sleep itself rather than focusing on one’s personal feelings or experiences. The same question also occurred in the studies conducted by Kang, et al
[47] on the Korean version and van Kooten, et al
[48] on the Dutch version, indicating the term “refreshing” is likely a suboptimal descriptor of sleep quality in this cultural context. Additionally, the factor loading of this item falling below 0.50 and the significant deviation of its ICC from the ideal curve both corroborate the earlier observation. To improve comprehension, cognitive interview is demanded to clarify participants’ understanding and adjust the description of this item. To enhance participants’ comprehension and ensure accurate responses, a cognitive interview is recommended to explore how participants interpret this item and refine the wording accordingly, thereby improving the reliability of this item. In its current form, this item should be interpreted in conjunction with the overall scale score and related items, rather than used in isolation for clinical decision-making.
The proportion of best score for physical function domain accounts for 42.2% of the whole cohort, manifesting a huge ceiling effect, which may limit the instrument’s ability to distinguish individuals with higher levels of PF. Adversely, the pain interference domain was noted significant floor effect of 37.4% of the worst score, making it difficult to differentiate among individuals with minimal pain interference. These findings were similar to the results of a validation study among kidney transplant recipients
[19]. Since each subscale of the PROMIS-29 contains only 4 items, they reduce the response burden, but at the same time also limit the depth and breadth of information that can be obtained
[49-50]. Another contributing factor could be that all participants were in stable condition and had received dialysis or transplant for at least 3 months, thereby resulting in better performance in the physical function and pain interference domains. In clinical practice, changes in patients with extreme scores may be underestimated. Therefore, this limitation should be considered when using these two domains to monitor treatment response or disease progression in KRT populations.
It is noteworthy that several PROMIS-29 domains showed only moderate correlations with their SF-12 counterparts. Although the SF-12 and PROMIS-29 assess similar health domains, their operational definitions are not fully aligned. For example, the SF-12 VT domain reflects positive states such as “feeling energetic”, whereas the PROMIS fatigue domain focuses on negative experiences such as “feeling tired or run-down”. In addition, the SF-12 uses only one to 2 items per domain, whereas the PROMIS-29 was developed using IRT with more comprehensive, construct-focused item banks. These differences may partly explain the attenuated correlations between the 2 instruments. Therefore, instrument selection should be guided by specific research purposes.
Measurement invariance and DIF are crucial in evaluating measures to mitigate bias and ensure comparability across different groups
[51-52]. In the current study, DIF was detected only for item PFA21 across education and treatment groups, and no DIF was detected for the remaining items. Similarly, McMullen, et al
[53] did not find any DIF in PROMIS-29 items among adult burn survivors across age, gender, education levels and burn size. Nevertheless, owing to the cross-sectional nature of our study design, we were unable to examine DIF over time, which is also crucial for measurement equivalence analysis
[54]. Future longitudinal studies are needed to investigate temporal measurement consistency.
As item banks in PROMIS were developed based on IRT, we plotted the ICCs and TICs to provide a more detailed and comprehensive understanding of psychometric properties. Both types of curves were analyzed with GRM, a model proposed by Samejima, et al
[55-56] that is suitable for ordered polytomous categories. Most items showed near-ideal shapes in their ICC plots, mirroring findings observed in a similar study involving a Chinese population with breast cancer
[19]. Test information was aggregated from the item information of all items within their respective domains. In this study, the test information of PROMIS-29 most subscales ranged from 10 to 30. Rimehaug, et al
[57] compared the test information between PROMIS-29 and PROMIS-57, finding that the curves of the shorter profile were under those of the longer one. In previous studies, the test information of 8-item short forms consistently surpassed the threshold of 30
[19, 58]. When selecting measurement tools for clinical or research purposes, considerations regarding brevity, validity, and precision of the tool should be thoroughly addressed. Though PROMIS-29 may offer less precision in providing information than PROMIS-57, its satisfactory psychometric properties and lower response burden render it favored in outcomes measurement.
Our study showcased the satisfactory reliability and validity of PROMIS-29 among adult patients with KRT in China. With its coverage of 7 domains closely linked to HRQoL encompassing physical, mental, and social aspects, this tool proves invaluable in assessing HRQoL and related symptoms like fatigue, anxiety, and depression
[59]. PROMIS-29 is a generic PROM with fewer items and less response burden, making it preferred for regular surveys in clinical settings. However, it is worth noting that in many instances, a combination of generic and disease-specific tools is essential to furnish more comprehensive information for clinical diagnosis, treatment, and care.
There are several limitations of our study that should be considered. First, we did not assess psychometric properties over time, such as test-retest reliability, time measurement invariance, and responsiveness. Future research employing longitudinal study designs are needed to address these aspects. Second, the standardized T-scores utilized in our study were derived from US norms, as no norms specific to the Chinese general population were available. Third, this study was a single-center study conducted in Hunan Province, which may limit the generalizability of our findings. A multi-center survey should be considered in the future. Fourth, our study employed convenience sampling to recruit participants, which may introduce bias and further limit. However, the inclusion of patients undergoing hemodialysis, peritoneal dialysis, and kidney transplantation extends the applicability of our findings across different treatment modalities.
In conclusion, this study provides evidence endorsing the reliability and validity of the Chinese version of PROMIS-29 in patients undergoing KRT. Combined with its advantages of comparability, simplicity, and precision, we recommend its consideration for assessing HRQoL and symptoms in these populations. Future studies could explore its acceptability, applicability, and utility in collecting clinical outcomes pertinent to CKD.
Contributions: ZHAO Qin Conceptualization, formal analysis, writing-original draft; WANG Liang and WANG Yu Investigation, data curation, methodology; ZHAO Hongyu, DONG Lei, and LIU Shan Methodology, validation; ZHU Xiao Methodology, validation, funding acquisition; LUO Haibo Methodology, visualization, writing-review & editing; LIU Jia Conceptualization, funding acquisition, writing- review & editing. The final version of the manuscript has been read and approved by all authors.
©Journal of Central South University (Medical Science). All rights reserved.