Based on near-infrared spectroscopy (NIRS) and modified Beer-Lambert law (MBLL), a new method for measuring oxygen content in vitro blood was proposed, at the same time, a blood oxygen saturation real-time monitoring system was developed to realize continuous monitoring of blood oxygen parameters during cardiopulmonary bypass. NIRS computes the absorption and scattering coefficients of tissues by using the difference in the absorption rates of the two wavelengths of near-infrared light by deoxyhemoglobin and oxygenated hemoglobin. Beer-Lambert law is a mathematical expression that characterizes the relationship between light intensity attenuation and photon transmission path. Combining the two can estimate the absorption coefficient of hemoglobin. Different from the traditional measurement method, the transmission measurement method proposed in this paper can obtain multi-parameter optical signal by alternating the probe of double wavelength (660‒904 nm) light source. The signal was uploaded to the acquisition interface (LabVIEW) in real time and processed by logarithm, a linear model of blood absorption coefficient, oxygenation and optical signals was developed using an innovative blood oxygen algorithm. In order to verify the feasibility of the research scheme, the experiments of liquid phantom and in vitro blood solution were carried out, and the volume of Ink Drop (phantom experiment) and yeast (blood solution experiment) were taken as variables, by adjusting the concentration of solution to change the change amplitude of optical density, it was proved that both of them had a good linear relationship with optical density ()(r2>0.95, p<0.01)). The novel oximetry method and real-time oximetry monitoring system proposed in this study are suitable for oximetry of isolated blood, with accurate and reliable data, good repeatability and stability.
CHUZ, WANGY, YOUG, et al. The P50 value detected by the oxygenation-dissociation analyser and blood gas analyser[J]. Artificial Cells, Nanomedicine, and Biotechnology, 2020, 48(1): 867-874.
YANXinzhong, YANGJing, GUOLue. Study on measuring method of human oxygen saturation [J]. Chinese Journal of Medical Device, 2005, 18(12): 1-4.(in Chinese)
WANGZhao, LIANGHong, WANGJiachen, et.al. Investigation on new paradigm of clinical physiological monitoring by using wearable devices[J]. Journal of Biomedical Engineering,2021,38(4): 753-763.
ZHAIJingfang, WUZijian, WUJiebin, et al. Clinical application of Excel spreadsheet with blood gas analysis in automatic judging the type of acid-base balance disorder[J]. Chinese Critical Care Medicine, 2020,32(8): 976-981. (in Chinese)
LIZengyong, DAIShixun, ZHANGXiaoyin, et al.Assessment of cerebral oxygen saturation using near infrared spectroscopy under driver fatigue state[J]. Spectroscopy and Spectral Analysis, 2010,30(1): 58 -61. (in Chinese)
LIUSongyang, LIUGuangda, LIUZhuoya, et al. Research on extended Kalman filter in extracting cerebral blood flow signals by near infrared spectroscopy[J]. Spectroscopy and Spectral Analysis, 2020,40(7): 2048-2053.(in Chinese)
ZHANGXiaoqing, SUNXiaoliang, PANQinghua, et al. The advancement of attenuated total reflection Fourier transform infrared technology in clinical application[J]. Spectroscopy and Spectral Analysis, 2017,37(2): 408-411. (in Chinese)
WANGXiaofei, ZHAOWenjun. Measurement of multi-wavelength pulse oxygen saturation based on dynamic spectroscopy[J]. Spectroscopy and Spectral Analysis,2014, 34(5): 1323-1326. (in Chinese)
LIQingbo, HANQingyang. The method of removing high-frequency noise in pulse wave signal in detecting oxygen saturation of human[J]. Spectroscopy and Spectral Analysis, 2012,32(9): 2523-2527. (in Chinese)
CHENNing, YOUTian. Influencing factors of pulse oxygen saturation measurement accuracy[J]. China Medical Engineering, 2021,29(5): 13 -16. (in Chinese)
[22]
LIUH, BOASD A, ZHANGY, et al. Determination of optical properties and blood oxygenation in tissue using continuous NIR light[J]. Physics in Medicine & Biology, 1995, 40(11): 1983-1993.
[23]
刘彩彩. 漫射光技术的深层组织血流测量算法研究[D]. 太原: 中北大学,2020.
[24]
张鹏. 近红外漫射光血流测量的N阶线性算法的去噪研究[D]. 太原: 中北大学,2019.
[25]
ZOUY, ZHOUX. Oxygen reserve index: A new method for monitoring oxygen therapy[J]. Chinese Journal of Contemporary Pediatrics, 2022,24(11): 1275-1280.
SUGuobao, XIXi, LIUXiaochen, et al. Effects of beating and cardiopulmonary bypass on cardiopulmonary function, hemodynamics and inflammation after coronary artery bypass grafting[J]. Chinese Journal of Experimental Surgery, 2022, 39(5): 844-846. (in Chinese)
YANGQingguo, CHENJun, XIAOGuilin. Design and implementation of multi-channel serial communication interface based on TMS320C6748[J]. Application of Electronic Technique, 2019, 45(7): 59-62. (in Chinese)
CHENJunbao, LIJie, LIUYong, et al. Research on the measurement method for instantaneous rotation speed based on the data acquisition card[J].Machine Tool & Hydraulics,2020,48(13): 26-29.(in Chinese)
CAOJuwen. Application of internet of things technology in power tunnel automatic early warning system of power tunnel[J]. Electronic Test, 2022(6): 69-71. (in Chinese)
[39]
CUIP, WANGQ, LIZ, et al. A feasibility study on improving the non-invasive detection accuracy of bottled Shuanghuanglian oral liquid using near infrared spectroscopy[J]. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2022, 274: 121120.
[40]
LIUJ, FUY, HANT, et al. Analysis of spectral characteristics of human body based on direct measurement of effective attenuation coefficient[J]. Spectroscopy and spectral analysis, 2022,42(9): 2746-2751.
LIMengze, JIZhong, CHENGJinxiu, et al. Realization of non-invasive blood glucose detector based on nonlinear auto regressive model and dual-wavelength[J]. Journal of Biomedical Engineering, 2021,38(2): 342-350. (in Chinese)
[44]
IRWIND, DONGL, SHANGY, et al. Influences of tissue absorption and scattering on diffuse correlation spectroscopy blood flow measurements[J]. Biomedical optics express, 2011, 2(7): 1969-1985.
GUOHaifeng, YANGKang. The prophase research on medical treatment optics CT imaging—experimentation of phase modulation device measure hererogeneous saturation on simulate biology[J]. Chinese Journal of Medical Physics, 2004,21(5): 300-301.(in Chinese)
LIJie, ZHANGXuerui, CHENZhongru, et al. Correction effect of platelets preserved with Qingkailing injections in vitro model of massive blood loss[J]. Journal of Clinical Transfusion and Laboratory Medicine, 2023,25(1): 88-96. (in Chinese)