The ±800 kV ultra high voltage (UHV) long cantilever transmission tower cross-arm structure belongs to a high-level horizontal long cantilever structure sensitive to the vertical seismic effect. It is urgent to conduct vertical seismic fragility analysis research on cross-arm structures. To address this, a framework for vertical seismic fragility analysis, considering multiple performance levels, was proposed for the UHV long cantilever transmission tower cross-arm structure. Firstly, a finite element model was established with the UHV long cantilever transmission tower as the research object, and the vertical dynamic characteristics of the structure were analyzed. Secondly, based on the stress ratio of the main component at the end of the cross-arm structure, multiple performance levels for slight, moderate, and severe damage to the cross-arm structure were established. Finally, a vertical seismic fragility analysis based on a probabilistic seismic demand model was carried out for the cross-arm structure. The analysis results show that the long cantilever transmission tower is significantly affected by higher-order vibration modes under vertical earthquake, and the first three vertical modes that contribute significantly to the vertical response of the structure are the 16th, 26th, and 29th modes, respectively. Under vertical seismic action, the end main component is the main load-bearing member of the cross-arm structure. Compared with considering the strength failure of the main component in tension bending at the end of the cross-arm structure, the failure probability of the cross-arm structure considering the instability failure of the main material in compression bending is significantly higher under the given vertical seismic intensity.
TANGG F, PANGH, HEZ Y .R & D and application of advanced power transmission technology in China[J].Proceedings of the CSEE,2016,36(7):1760-1771.(in Chinese)
WANGL, LIZ L, WANGT. Seismic reliability analysis of transmission tower-line coupling system considering SSI effect[J]. Journal of Hunan University (Natural Sciences),2023,50(11): 192-203.(in Chinese)
[7]
TUZ B, YAOJ F, XUH W,et al .Influence of refined wind load parameters and wind-loading mode on wind-induced responses of a long cross-arm angle-steel transmission tower[J]. International Journal of Structural Stability and Dynamics,2022,22(6): 2250074.
LOUW J, JIANGY, JINX H,et al. Wind tunnel test research on wind-induced vibration characteristics of angle steel tower in typhoon field[J]. Journal of Vibration Engineering, 2013, 26(2):207-213.(in Chinese)
SHENG H, LIB H, GUOY,et al .Calculation methods of torsion response and torsion equivalent static wind loading of transmission tower[J].Journal of Zhejiang University (Engineering Science),2022, 56(3): 579-589.(in Chinese)
[12]
TIANL, YANGM, LIUS Y,et al. Collapse failure analysis and fragility analysis of a transmission tower-line system subjected to the multidimensional ground motion of different input directions[J]. Structures, 2023, 48: 1018-1028.
[13]
FADEL MIGUELL F, ALMINHANAF, BECKA T .Performance based assessment of transmission lines to seismic events[J].Engineering Structures,2021,249:113298.
[14]
Pacific earthquake engineering research center. Ground motion database[DB/OL].(2020-01-30)[2023-12-25].
[15]
PARKH S, CHOIB H, KIMJ J,et al .Seismic performance evaluation of high voltage transmission towers in South Korea[J].KSCE Journal of Civil Engineering,2016,20(6):2499-2505.
[16]
王新敏. ANSYS工程结构数值分析[M].北京:人民交通出版社, 2007.
[17]
WANGX M. Numerical analysis of ANSYS engineering structure[M]. Beijing:People’s Communications Press, 2007.(in Chinese)
LOUM L, ZHANGJ. Discussion on damping models for seismic response analysis of long-span bridge[J]. Journal of Vibration and Shock, 2009,28(5): 22-26.(in Chinese)
ZHANGY T, DUX J, YANGL. Research on seismic performance assessment based on component damage for RC frame structure[J]. Journal of Hunan University (Natural Sciences), 2016, 43(5): 9-21. (in Chinese)
GUQ, YUZ Q, QIUZ J. Seismic risk assessment of an liquefaction ground bridge system using stone column for reinforcement[J]. Journal of Hunan University (Natural Sciences), 2022, 49(7): 178-185. (in Chinese)
LIX H, LIY X, WUD,et al .Correlation between ground motion intensity and structural seismic response[J].Journal of Vibration and Shock,2014,33(23):184-189.(in Chinese)
YUD K, LIZ L, HANF,et al .Reliability analysis on ultra-high voltage transmission tower under wind based on performance[J].Journal of Disaster Prevention and Mitigation Engineering,2013,33(6): 657-662.(in Chinese)
LIH N, ZHANGW S, FUX .Fragility assessment of a transmission tower subjected to wind load based on big data and deep learning[J].China Civil Engineering Journal,2022,55(9):54-64.(in Chinese)
[38]
CORNELLC A, JALAYERF, HAMBURGERR O,et al .Probabilistic basis for 2000 SAC federal emergency management agency steel moment frame guidelines[J].Journal of Structural Engineering,2002,128(4): 526-533.
[39]
Quantification of building seismic performance factors: FEMA-P695 [S]. Washington: Federal Emergerrcy Management Agency, 2009: 275-279.
基金资助
重庆市自然科学基金面上项目(CSTB2024NSCQ-MSX1134)
Natural ScienceFoundation of Chongqing(CSTB2024NSCQ-MSX 1134)
重庆市博士后研究特别资助项目(2022CQBSHBT3009)
Special Supported by Chongqing Postdoctoral Research Project(2022 CQBSHBT3009)