To develop a damage assessment model applicable to a glued-laminated timber post and beam structural system and gain insights into its behavior under seismic conditions, a series of tests were conducted on four full-scale specimens subjected to horizontal loading. Various aspects, including the presence or absence of braces, different horizontal loading procedures, and two types of K-braces were taken into account. The obtained test results indicate that the failure mode of the pure framework is primarily concentrated at the joints and accompanied by large horizontad deformation. In contrast, specimens equipped with K-braces predominantly experienced failure modes marked by the instability of the brace components. Integrating the K-brace into the glued-laminated timber post and beam structural system effectively enhances the structure’s stiffness and maximum load-carrying capacity while reducing lateral deformations. Additionally, based on the experimental data and the failure characteristics of the specimens, a dual-parameter evaluation model considering deformation and energy dissipation was proposed. This model was capable of reflecting the damage caused by large deformations in the early stages of specimen failure and had the potential to provide a reliable theoretical basis for the reinforcement and design of the glued-laminated timber post and beam structural system and their supported components.
图3所示为循环加载制度[18],其中∆m是从单调加载中获得的极限位移值.正式加载前先进行预加载,方法同单调加载.正式加载分为两个阶段:第一阶段采用Δm的1.25%、2.5%、5%、7.5%和10%依次进行一个循环的三角形波加载;第二阶段采用Δm的20%、40%、60%、80%、100%和120%依次进行3个循环的三角形波加载,直至试验终止,每个循环的持续时间均为3 min.
CAOJ X, DUJ D, FANQ,et al. Enhancement of mechanical characteristics and novel damage assessment for timber post and beam structures with K-braces[J]. Journal of Building Engineering, 2024, 95: 110300.
[2]
BAIF Y, FANZ K, XUEJ Y, et al. Experimental study on seismic performance and deformation damage of loose dovetail-tenon joints in ancient timber structures[J]. Structures, 2023, 54: 541-555.
[3]
SCHNEIDERJ, SHENY, STIEMERS F, et al. Assessment and comparison of experimental and numerical model studies of cross-laminated timber mechanical connections under cyclic loading[J].Construction and Building Materials, 2015, 77: 197-212.
XUEJ Y, ZHANGF L, ZHAOH T,et al .Potential and energy dissipation-based seismic damage evaluation of ancient timber structure[J].Journal of Building Structures,2012,33(8):127-134.(in Chinese)
[8]
孙丽月. 基于能量耗散准则的光岳楼木结构地震损伤评 估[D]. 聊城: 聊城大学, 2022.
[9]
SUNL Y .Earthquake damage assessment of Guangyue tower timber structure based on energy dissipation criterion[D].Liaocheng:Liaocheng University,2022.(in Chinese)
WUY J, SONGX B, JIANGH Y,et al .Experimental study on lateral performance of glulam timber frames with timber-steel buckling-restrained bracings[J].Journal of Building Structures,2021, 42(7): 38-46.(in Chinese)
XUQ F, ZHANGF W, MAY R,et al .Shaking table test on a five-story post-and-beam glulam structure[J]. China Civil Engineering Journal, 2018, 51(12):52-62.(in Chinese)
[16]
YOUSEF-BEIKS M M, BAGHERIH, VEISMORADIS, et al. Seismic performance improvement of conventional timber brace using recentring friction connection [J]. Structures, 2020, 26: 958-968.
XUEJ Y, RENG Q, YUANZ, et al. Experimental study on seismic performance of glued-laminated timber frame infilled with CLT shear wall[J]. Journal of Building Structures,2022,43(11):140-150.(in Chinese)
GAOY, SONGX B .Synergistic lateral resistance performance of cross-laminated timber walls and tension-only braced frames[J].Journal of Building Structures,2025,46(2):39-49.(in Chinese)
LIZ, WANGZ W, HEM J,et al .Experimental and numerical investigations into mechanical performance of key connections in multi-story timber frame structures with cross laminated timber (CLT) shear walls[J].China Civil Engineering Journal, 2024,57(11): 1-13.(in Chinese)
XIEQ F, ZHANGY, YANZ L,et al .Seismic performance of glulam timber frame with wooden frictional rotational connections:experimental study and theoretical analysis[J].China Civil Engineering Journal,2023,56(7):34-44.(in Chinese)
[25]
Standard practice for static load test for shear resistance of framed walls for buildings:ASTM E564-06 [S]. West Conshohocken: ASTM International, 2012.
[26]
XIONGH B, LIUY Y. Experimental study of the lateral resistance of bolted glulam timber post and beam structural systems [J]. Journal of Structural Engineering, 2016, 142(4): E4014002.
[27]
XUEJ Y, YUANZ, RENG Q, et al. Seismic performance of glued-laminated wood frame and frame brace structure: Experimental and finite element analysis [J]. Journal of Building Engineering, 2022, 48: 103944.
[28]
Standard test methods for cyclic (reversed) load test for shear resistance of vertical elements of the lateral force resisting systems for buildings :ASTM E2126-11 [S]. West Conshohocken: ASTM International, 2012.
XIONGH B, LIUY Y, YANGC M,et al. Experimental study on lateral resistance of glued-laminated timber post and beam systems[J]. Journal of Tongji University (Natural Science), 2014, 42(8): 1167-1175.(in Chinese)
[31]
CAOJ X, DUJ D, FANQ,et al .Reinforcement for earthquake-damaged glued laminated timber knee-braced frames with self-tapping screws and CFRP fabric[J].Engineering Structures,2024, 306:117787.
[32]
KRATZIGW B, MEYERIF, MESKOURISK. Damage evolution in reinforced concrete members under cyclic loading [C]// The 5th International Conference on Structural Safety and Reliability. San Francisco (CA): ASCE, 1989: 795-804.
[33]
PARKY J, ANGA H .Mechanistic seismic damage model for reinforced concrete[J].Journal of Structural Engineering,1985,111(4):722-739.
[34]
PARKY J, ANGA H, WENY K. Seismic damage analysis of reinforced concrete buildings[J]. Journal of Structural Engineering, 1985, 111(4):740-757.