特征谱线矩阵与样品聚类辅助的钢铁中铬元素激光诱导击穿光谱(LIBS)定量分析

郑培超 ,  张文硕 ,  王金梅 ,  代攀杨 ,  李思琪 ,  张艺 ,  黄浩轩

中国无机分析化学 ›› 2026, Vol. 16 ›› Issue (11) : 1969 -1979.

PDF (6493KB)
中国无机分析化学 ›› 2026, Vol. 16 ›› Issue (11) : 1969 -1979. DOI: 10.20236/j.CJIAC.2026.11.001
有毒与有害物质(专栏)

特征谱线矩阵与样品聚类辅助的钢铁中铬元素激光诱导击穿光谱(LIBS)定量分析

作者信息 +

Quantitative LIBS Analysis of Chromium in Steels Assisted by a Characteristic Spectral-line Matrix and Sample Clustering

Author information +
文章历史 +
PDF (6647K)

摘要

成分跨度较大的钢铁样品存在明显的基体依赖响应,全谱建模又包含大量冗余变量。在保持谱线物理归属和低维表达的前提下,评价样品聚类对钢铁中Cr定量的作用。将27条样品平均光谱作为独立建模单元,经稀疏性基线估计与去噪(BEADS)处理后提取Fe、Cr、Ni、Mn、Mo和Ti共23条特征谱线的峰面积,以Fe Ⅰ 271.902 nm谱线构建内标比值;采用主成分分析(PCA)与K-means++形成K=3分组,并在外层留一法(逐样品留一)过程中,将积分窗口选择、标准化、PCA、聚类、留出样品归类及偏最小二乘(PLS)潜变量选择全部限制在训练折内。K-means++与高斯混合模型(GMM)均得到11、9和7个样品的相同分组;27个外层折的训练样品分组与全样本描述性分组的调整兰德指数(ARI)均为1.000。Fe Ⅰ 271.902 nm在4条候选Fe谱线中具有最低的峰面积相对标准偏差(RSD)中位数,但内标校正对不同分析线的重复性影响具有谱线依赖性。各模型的负预测值在汇总评价前按质量分数非负边界置为0。非负后处理后,K=3 聚类辅助偏最小二乘回归(Cluster-PLSR)模型获得决定系数(R2)、均方根误差(RMSE)、平均绝对误差(MAE)和性能偏差比(RPD)分别为0.953 1、1.886%、1.314%和4.70;相对于相同23变量的全局Fe内标PLSR,RMSE降低43.24%。与16 355个变量的全谱模型相比,特征变量数减少99.86%。物理可解释的特征谱线矩阵结合成分感知分组,可在所研究钢样范围内显著改善低维全局模型性能;全谱模型仍保持最高绝对精度,本文方法的主要价值在于变量轻量化和结果可解释性。

Abstract

Matrix-dependent responses and high-dimensional redundancy hinder quantitative laser-induced breakdown spectroscopy (LIBS) analysis of compositionally diverse steels. This study aimed to evaluate whether composition-aware clustering can improve a physically interpretable low-dimensional model for chromium determination. Twenty-seven sample-mean spectra were treated as independent modeling units. After correction using baseline estimation and denoising with sparsity (BEADS), peak areas of 23 Fe, Cr, Ni, Mn, Mo and Ti lines were extracted and referenced to Fe Ⅰ 271.902 nm. Integration-window selection, standardization, principal component analysis (PCA), K=3 clustering, held-out-sample assignment and partial least squares (PLS) latent-variable selection were reconstructed inside every outer sample-wise leave-one-out cross-validation (LOOCV) training fold. Negative outer-fold predictions were mapped to zero according to the nonnegative physical boundary before metric calculation. K-means++ and Gaussian mixture model (GMM) produced the same 11/9/7 grouping, and the adjusted Rand index of the training-sample partition was 1.000 in all 27 outer folds. Fe I 271.902 nm had the lowest median peak-area relative standard deviation (RSD) among four Fe candidates, whereas the effect of Fe referencing on repeatability was line-dependent. K=3 cluster-assisted partial least squares regression (PLSR) achieved a coefficient of determination (R2) of 0.953 1, a root mean square error (RMSE) of 1.886%, a mean absolute error (MAE) of 1.314% and a ratio of performance to deviation (RPD) of 4.70, reducing RMSE by 43.24% relative to global PLSR using the same 23 variables. The variable count was reduced by 99.86% compared with the 16 355-variable full-spectrum model. Composition-aware local modeling recovered much of the predictive capability lost by low-dimensional global modeling while retaining explicit elemental assignments. The full-spectrum model remained the most accurate in absolute terms; therefore, the principal advantage of the proposed strategy is lightweight and interpretable calibration within the studied composition range.

关键词

激光诱导击穿光谱 / 钢铁分析 / 铬 / 特征谱线 / 聚类分析 / 偏最小二乘回归

Key words

laser-induced breakdown spectroscopy / steel analysis / chromium / characteristic spectral lines / clustering / partial least squares regression

引用本文

引用格式 ▾
郑培超,张文硕,王金梅,代攀杨,李思琪,张艺,黄浩轩. 特征谱线矩阵与样品聚类辅助的钢铁中铬元素激光诱导击穿光谱(LIBS)定量分析[J]. 中国无机分析化学, 2026, 16(11): 1969-1979 DOI:10.20236/j.CJIAC.2026.11.001

登录浏览全文

4963

注册一个新账户 忘记密码

参考文献

[1]

Hahn D W,Omenetto N. Laser-induced breakdown spectroscopy (LIBS),part Ⅰ:review of basic diagnostics and plasma-particle interactions:still-challenging issues within the analytical plasma community[J]. Applied Spectroscopy,2010,64(12):335A-366A.

[2]

Hahn D W,Omenetto N. Laser-induced breakdown spectroscopy (LIBS),part Ⅱ:review of instrumental and methodological approaches to material analysis and applications to different fields[J]. Applied Spectroscopy,2012,66(4):347-419.

[3]

El Haddad J,Canioni L,Bousquet B. Good practices in LIBS analysis:review and advices[J]. Spectrochimica Acta Part B:Atomic Spectroscopy,2014,101:171-182.

[4]

Bol'shakov A A,Yoo J H,Liu Chunyi,et al. Laser-induced breakdown spectroscopy in industrial and security applications[J]. Applied Optics,2010,49(13):C132-C142.

[5]

Noll R,Bette H,Brysch A,et al. Laser-induced breakdown spectrometry:applications for production control and quality assurance in the steel industry[J]. Spectrochimica Acta Part B:Atomic Spectroscopy,2001,56(6):637-649.

[6]

Noll R,Fricke-Begemann C,Brunk M,et al. Laser-induced breakdown spectroscopy expands into industrial applications[J]. Spectrochimica Acta Part B:Atomic Spectroscopy,2014,93:41-51.

[7]

Aragón C,Aguilera J A,Peñalba F. Improvements in quantitative analysis of steel composition by laser-induced breakdown spectroscopy at atmospheric pressure using an infrared Nd:YAG laser[J]. Applied Spectroscopy,1999,53(10):1259-1267.

[8]

Vrenegor J,Noll R,Sturm V. Investigation of matrix effects in laser-induced breakdown spectroscopy plasmas of high-alloy steel for matrix and minor elements[J]. Spectrochimica Acta Part B:Atomic Spectroscopy,2005,60(7/8):1083-1091.

[9]

Shah M L,Pulhani A K,Gupta G P,et al. Quantitative elemental analysis of steel using calibration-free laser-induced breakdown spectroscopy[J]. Applied Optics,2012,51(20):4612-4621.

[10]

Zeng Qingdong,Guo Lianbo,Li Xiangyou,et al. Quantitative analyses of Mn,V,and Si elements in steels using a portable laser-induced breakdown spectroscopy system based on a fiber laser[J]. Journal of Analytical Atomic Spectrometry,2016,31(3):767-772.

[11]

Li Kuohu,Guo Lianbo,Li Jiaming,et al. Quantitative analysis of steel samples using laser-induced breakdown spectroscopy with an artificial neural network incorporating a genetic algorithm[J]. Applied Optics,2017,56(4):935-941.

[12]

Afgan M S,Hou Zongyu,Wang Zhe. Quantitative analysis of common elements in steel using a handheld μ-LIBS instrument[J]. Journal of Analytical Atomic Spectrometry,2017,32(10):1905-1915.

[13]

Kim H,Nam S H,Han S H,et al. Laser-induced breakdown spectroscopy analysis of alloying elements in steel:partial least squares modeling based on the low-resolution spectra and their first derivatives[J]. Optics & Laser Technology,2019,112:117-125.

[14]

Yan Jiujiang,Hao Zhongqi,Zhou Ran,et al. A quantitative analysis method assisted by image features in laser-induced breakdown spectroscopy[J]. Analytica Chimica Acta,2019,1082:30-36.

[15]

Zhang Tianlong,Xia Donghui,Tang Hongsheng,et al. Classification of steel samples by laser-induced breakdown spectroscopy and random forest[J]. Chemometrics and Intelligent Laboratory Systems,2016,157:196-201.

[16]

Pořízka P,Klus J,Prochazka D,et al. Laser-Induced Breakdown Spectroscopy coupled with chemometrics for the analysis of steel:the issue of spectral outliers filtering[J]. Spectrochimica Acta Part B:Atomic Spectroscopy,2016,123:114-120.

[17]

吴卓,苏晓慧,范博文, 不同特征选择方法结合激光诱导击穿光谱量化不锈钢镍、钛和铬元素含量[J]. 光谱学与光谱分析,2024,44(12):3339-3346.

[18]

Wu Zhuo,Su Xiaohui,Fan Bowen,et al. Different feature selection methods combined with laser-induced breakdown spectroscopy were used to quantify the contents of nickel,titanium and chromium in stainless steel[J]. Spectroscopy and Spectral Analysis,2024,44(12):3339-3346.

[19]

汪倩,钟绪,李国文, 基于LIBS-CNN协同优化的结构金属材料中痕量Cr元素的定量分析[J]. 中国激光,2025,52(22):2211003.DOI:10.3788/CJ250598.

[20]

Wang Qian,Zhong Xu,Li Guowen,et al. Quantitative analysis of trace chromium element in structural metal materials based on LIBS-CNN collaborative optimization[J]. Chinese Journal of Lasers,2025,52(22):2211003.DOI:10.3788/CJ250598.

[21]

李婉雪,何亚雄,李杨, 激光诱导击穿光谱结合机器学习算法的同基合金快速识别研究[J]. 激光与光电子学进展,2024,61(17):1730001.DOI:10.3788/LOP232417.

[22]

Li Wanxue,He Yaxiong,Li Yang,et al. Rapid identification of homogeneous alloys based on laser-induced breakdown spectroscopy combined with machine-learning algorithms[J]. Laser & Optoelectronics Progress,2024,61(17):1730001.DOI:10.3788/LOP232417.

[23]

Brunnbauer L,Gajarska Z,Lohninger H,et al. A critical review of recent trends in sample classification using Laser-Induced Breakdown Spectroscopy (LIBS)[J]. TrAC Trends in Analytical Chemistry,2023,159:116859. DOI:10.1016/j.trac.2022.116859.

[24]

Zheng Peichao,Chen Guanghui,Gu Weilun,et al. Upgrade from signal enhancement to plasma modulation for LIBS signal improvement[J]. TrAC Trends in Analytical Chemistry,2026,197:118709. DOI:10.1016/j.trac.2026.118709.

[25]

Tognoni E,Cristoforetti G,Legnaioli S,et al. Calibration-free laser-induced breakdown spectroscopy:state of the art[J]. Spectrochimica Acta Part B:Atomic Spectroscopy,2010,65(1):1-14.

[26]

Zorov N B,Gorbatenko A A,Labutin T A,et al. A review of normalization techniques in analytical atomic spectrometry with laser sampling:from single to multivariate correction[J]. Spectrochimica Acta Part B:Atomic Spectroscopy,2010,65(8):642-657.

[27]

Guezenoc J,Gallet-Budynek A,Bousquet B. Critical review and advices on spectral-based normalization methods for LIBS quantitative analysis[J]. Spectrochimica Acta Part B:Atomic Spectroscopy,2019,160:105688. DOI:10.1016/j.sab.2019.105688.

[28]

Wold S,Sjöström M,Eriksson L. PLS-regression:a basic tool of chemometrics[J]. Chemometrics and Intelligent Laboratory Systems,2001,58(2):109-130.

[29]

Ning Xiaoran,Selesnick I W,Duval L. Chromatogram baseline estimation and denoising using sparsity (BEADS)[J]. Chemometrics and Intelligent Laboratory Systems,2014,139:156-167.

[30]

Silva N A,Capela D,Ferreira M,et al. Towards robust calibration models for laser-induced breakdown spectroscopy using unsupervised clustered regression techniques[J]. Results in Optics,2022,9:100245. DOI:10.1016/j.rio.2022.100245.

[31]

Reunanen J. Overfitting in making comparisons between variable selection methods[J]. Journal of Machine Learning Research,2003,3:1371-1382.

[32]

Varma S,Simon R. Bias in error estimation when using cross-validation for model selection[J]. BMC Bioinformatics,2006,7(1):91. DOI:10.1186/1471-2105-7-91.

[33]

Cawley G C,Talbot N L C. On over-fitting in model selection and subsequent selection bias in performance evaluation[J]. Journal of Machine Learning Research,2010,11:2079-2107.

[34]

Kramida A,Ralchenko Y,Reader J,et al. NIST Atomic Spectra Database (version 5.12)[DB/OL]. Gaithersburg:National Institute of Standards and Technology,2024[<date-in-citation content-type="access-date">2026-07-28]. https://physics.nist.gov/asd.

基金资助

国家自然科学基金资助项目(62575044);重庆市自然科学基金资助项目(CSTB2024NSCQ-LZX0078);重庆市教委科技研究项目重大项目(KJZD-M202600608)

AI Summary AI Mindmap
PDF (6493KB)

0

访问

0

被引

详细

导航
相关文章

AI思维导图

/

〈 〉