极罕遇地震作用下无预紧力变摩擦惯容器消能体系抗震性能分析
赵桂峰 , 刘伟 , 马玉宏 , 孔思华 , 陈家川 , 陈兆升
工程科学与技术 ›› 2025, Vol. 57 ›› Issue (04) : 62 -70.
极罕遇地震作用下无预紧力变摩擦惯容器消能体系抗震性能分析
Seismic Performance Analysis of Energy Dissipation Building with Non-preload Variable Friction Inerter Under Extremely Rare Earthquake
针对传统摩擦阻尼器在极罕遇或近场脉冲型地震作用下需施加较大预紧力以提供足够的阻尼力,且可能引发耐久性问题这一现状,提出一种无预紧力变摩擦惯容器(NVFI)。首先,对NVFI的组成、工作原理及力学模型进行介绍,指出其通过滚珠丝杠驱动弹簧施加可变正压力,从而在摩擦片之间形成随运动变化的变摩擦阻尼力,呈现出“蝴蝶形”滞回曲线特征。其次,建立NVFI的恢复力计算公式,并以单自由度结构为算例,开展各级地震作用下的非线性动力时程分析,验证NVFI的减震效果和能量耗散能力。研究结果表明:NVFI可在无预紧力条件下实现大吨位的变摩擦阻尼力,有效降低结构位移、速度及加速度响应,且对近场脉冲型地震作用下的减震效果尤为突出。在设防地震水平下,NVFI可分别降低远场、近场脉冲型及非脉冲型地震作用下结构位移响应的46%、56%和34%,同时表现出较好的速度与加速度减震性能。能量分析显示,NVFI可显著降低结构输入的地震能量,改变结构基本频率,使之避开外界地震主频的影响范围。此外,通过分析质量比在0~0.5变化对结构动力响应的影响可知,质量比主要影响结构的速度和加速度响应,对位移响应影响相对较小;NVFI的减震与耗能性能主要依赖其优异的变摩擦阻尼特性,而惯容机制主要是降低地震输入能。
Objective Traditional energy dissipation technologies provide an effective solution to mitigate the seismic responses of buildings. There are two types of energy dissipation devices based on their operational characteristics: velocity-dependent dampers and displacement-dependent dampers. Friction dampers (FDs), as a category of displacement-dependent energy dissipation devices, exhibit several common advantages, such as good energy dissipation capacity, satisfactory mechanical performance, and ease of fabrication and installation. Therefore, they have received extensive attention from researchers in recent years. Buildings can require large damping forces under extremely rare or near-fault earthquake events, which necessitate that existing FDs apply a high preload to deliver sufficient reaction forces. However, introducing an excessive preload force can be impractical and uneconomical for current FDs. For example, the damping force of existing FDs can need to reach 1 000 kN for buildings subjected to a severe or near-fault earthquake event, resulting in a required preload force of 10 000 kN when the friction coefficient is assumed to be 0.1. In addition, FDs with a specified preload force still face durability issues such as cold bonding, cold solidification, and preload relaxation. Therefore, this study aims to develop a non-preload variable friction inerter (NVFI), which provides satisfactory damping force and significant energy dissipation without relying on preload force. Methods The proposed NVFI mainly consisted of a ball screw, rotational plate, friction plate, spring, and two thrust bearings. One terminal of the ball screw was fixed to the structure using an ear plate. The ball screw of the NVFI generated axial motion when the structure reciprocally shook under seismic earthquakes, and the springs were driven to reciprocal motion, resulting in a variable positive pressure of the friction plate. Therefore, the butterfly-shaped hysteretic behavior of the proposed NVFI was found based on the friction mechanism mentioned above. Then, the restoring force formula of the proposed NVFI was further established. Then, seismic performance mitigation of a single-degree-of-freedom (SDOF) system under different hazard levels was conducted to evaluate the effectiveness and advantages of the proposed NVFI quantitatively. A 5% damping SDOF system with a mass of 50 660 kg and elastic stiffness of 2 000 kN/m was adopted as the analytical model. A Bouc‒Wen elastoplastic model was employed in the SDOF system with a yield strength of 24 kN and post-elastic stiffness of 200 kN/m. The SDOF system with and without the proposed NVFI was considered and denoted as SDOF‒NVFI and SDOF, respectively. Three groups of different ground motion records, including far-field, near-fault pulse, and near-fault non-pulse ground motion records, were selected to perform the nonlinear dynamic analysis, and the peak ground acceleration (PGA) scaled to multiple intensity levels was 0.2g, 0.4g, and 0.6g for design level earthquake (DLE), maximum considered earthquake (MCE), and extremely rare earthquake (ERE), respectively. Results and Discussions The results illustrated that NVFI significantly reduced the displacement, velocity, and acceleration responses of the SDOF systems subjected to different earthquake records at different hazard levels. The average displacement reduction ratios were 46%, 56%, and 34% for the SDOF‒NVFI subjected to far-field, near-fault pulse, and near-fault non-pulse ground motions at the DLE hazard level, respectively. Similar reductions were also observed in the velocity and acceleration results. Compared to the results of the far-field and near-fault non-pulse ground motions, the displacement and velocity responses of the SDOF systems subjected to near-fault pulse ground motions were more effectively decreased using the proposed NVFI while maintaining a basically approximate acceleration mitigation effect. This is attributed to the fact that the proposed NVFI exhibits good energy dissipation capacity, which was induced by its unique friction mechanism. The satisfactory and variable friction force made the NVFI more suitable for buildings under seismic earthquakes with strong uncertainty, especially for near-fault pulse-such as earthquake events. On the other hand, the seismic input energy of the SDOF system was also decreased through the proposed NVFI. The seismic input energy of the SDOF‒NVFI system was less than 15 kJ at the MCE hazard level, while the seismic input energy of the SDOF system was greater than 24 kJ. This indicated that the fundamental frequency of the SDOF system can be effectively shifted from the dominant frequency of external disturbance by introducing the proposed NVFI, thus improving the overall performance of the structure. Finally, the parameter analysis of the SDOF‒NVFI systems considering different inertance-to-mass ratios was further performed to reveal the influence of the inerter mechanism from the proposed NVFI. The results illustrated that increasing the inertance-to-mass ratio of the proposed NVFI has a significant influence on the velocity and acceleration responses of the SDOF systems at the DLE hazard level while showing a slight but visible influence on the displacement response. Specifically, more than a 10% increase in the velocity and acceleration responses of the SDOF systems subjected to far-field ground motions at the DLE hazard level was observed, with the inertance-to-mass ratio increasing from 0.1 to 0.5. Conclusions The results indicated that the energy dissipation of the SDOF system primarily depends on the superior energy dissipation capacity of the NVFI due to the effectiveness of its variable friction mechanism, whereas the inerter serves only to transform the seismic input energy.
| [1] |
|
| [2] |
谭倩,吴谓,张耀庭.极罕遇地震作用下多层RC框架结构抗震性能分析[J].地震工程与工程振动,2019,39(4):170‒177. |
| [3] |
国家质量监督检验检疫总局,中国国家标准化管理委员会. 中国地震动参数区划图:GB 18306—2015 [S].北京:中国标准出版社,2016. |
| [4] |
|
| [5] |
李巧萍,赵敏.《中国地震动参数区划图》施行4周年[J].防灾博览,2020(3):19‒21. doi:10.3969/j.issn.1671-6310.2020.03.005 |
| [6] |
|
| [7] |
|
| [8] |
漆启明,邵长江,黄辉, |
| [9] |
|
| [10] |
王昱翔,叶昆.多级地震作用下LRB隔震多层结构抗震性能分析[J].建筑结构学报,2023,44(11):1‒14. |
| [11] |
|
| [12] |
虞终军,李歆,王建峰, |
| [13] |
|
| [14] |
吕大刚,周洲,王丛, |
| [15] |
|
| [16] |
王丛,吕大刚.风险导向地震动参数决策及参数影响分析[J].建筑结构学报,2020,41():44‒52. doi:10.14006/j.jzjgxb.2020.S2.0006 |
| [17] |
|
| [18] |
王丛,吕大刚.基于抗震规范和地震动区划图的风险导向地震动决策参数分析[J].建筑结构学报,2020,41(8):19‒28. |
| [19] |
|
| [20] |
徐铭阳,王丛,董尧, |
| [21] |
|
| [22] |
|
| [23] |
|
| [24] |
|
| [25] |
张冠平,刘彦辉,谭平, |
| [26] |
|
| [27] |
|
| [28] |
|
| [29] |
蒲瑞,李倩倩,王健泽, |
| [30] |
中华人民共和国住房和城乡建设部. 建筑消能减震技术规程:JGJ 297—2013 [S].北京:中国建筑工业出版社,2013. |
| [31] |
|
| [32] |
秦凯,閤东东,李培, |
| [33] |
|
| [34] |
|
| [35] |
|
| [36] |
石文龙,张浩波.摩擦阻尼器的研究进展[J].地震工程学报,2022,44(1):1‒16. |
| [37] |
|
| [38] |
张玉敏,谷玉珍.摩擦阻尼器在建筑结构减震应用的现状研究[J].建筑结构,2018,48():387‒392. |
| [39] |
|
| [40] |
刘云帅,韩建平,王晓琴.具自复位摩擦阻尼器的桥梁隔震性能研究[J].工程科学与技术,2018,50(6):77‒83. |
| [41] |
|
| [42] |
|
| [43] |
|
| [44] |
|
| [45] |
陈家川,赵桂峰,马玉宏, |
| [46] |
|
国家重点研发计划项目(2022YFC3801201)
国家重点研发计划项目(2019YFE0112500)
国家自然科学基金项目(52378499)
国家自然科学基金项目(52308488)
国家自然科学基金项目(52078150)
广东省基金面上项目(2023A1515010072)
/
| 〈 |
|
〉 |