Objective The widespread integration of power electronic devices contributes to a continuous decline in the inertia levels of modern power systems. Therefore, the accurate and rapid assessment of regional equivalent inertia is essential for developing refined regulation strategies and maintaining frequency stability. In this study, we introduce a novel method for rapidly assessing regional system inertia based on frequency prediction errors. Methods Power and frequency data within a target region were collected through a wide-area measurement system and converted into equivalent representations. During this equivalence process, regional power was represented by the aggregate power output of all internal generators, whereas regional frequency was characterized by the equivalent center-of-inertia frequency. The raw phasor measurement unit (PMU) data were preprocessed using an adaptive least mean squares (LMS) filtering algorithm to address the practical issue of measurement noise from commercial PMUs. The LMS algorithm was employed to adjust filter weights adaptively, which minimized the mean square error between the output signal and the desired response and effectively suppressed noise. In addition, by deriving a frequency prediction error formula, the regional inertia assessment problem was transformed into a single-variable root-finding problem, in which the objective was to determine the inertia value that reduced the error between the predicted and measured frequencies to zero. A collaborative estimation algorithm that combined binary search with error feedback was proposed. The core of this algorithm involved the use of 100 consecutive data points within a 1 s time window following a system disturbance for global optimization. Through iterative optimization of a global equivalent inertia variable using binary search, the optimal inertia value was determined in a single process, which effectively addressed the noise sensitivity issues associated with traditional point-by-point calculation methods. The performance of the proposed method was rigorously validated through multi-scenario simulation tests conducted on a modified IEEE 39-bus system in the DIgSILENT PowerFactory environment and through actual operational data from a provincial power grid using the PSASP platform. The test conditions included various disturbance locations, different levels of power shortage, and systems with high penetration levels of renewable energy sources. Results and Discussions Simulation results obtained from the IEEE 39-bus system, with and without integrated renewable generation, demonstrated the effectiveness of the proposed method (Method 1). Its performance was compared to that of a direct solving method (Method 2) and an autoregressive moving average with exogenous inputs model-based method (Method 3). In the scenario without renewable energy, the mean estimation errors for the three methods were 1.41%, 2.41%, and 1.61%, respectively, with corresponding computation times of 0.015 s, 0.025 s, and 0.146 s. Under the scenario with 33.23% renewable energy penetration, the mean errors were 1.53%, 3.16%, and 6.71%, with corresponding solution times of 0.014 s, 0.026 s, and 0.141 s. These results indicated that the proposed method maintained high estimation accuracy while achieving significantly faster solution speeds. A scenario with 52.6% renewable energy penetration was examined, in which the relative errors for regional inertia assessment were 0.31%, -1.88%, 0.12%, and -2.56%, which confirmed the robustness of the method and further assessed its adaptability to systems with high renewable energy penetration. Investigations into the effects of data window length and disturbance moment identification revealed that a data window of approximately 1 s (100 sampling points) provided an optimal balance between estimation accuracy and computational speed. The algorithm exhibited low sensitivity to deviations in the initial moment, which enhanced its practical applicability by mitigating the effects of data synchronization errors in real-world engineering applications. Four distinct disturbance scenarios were established for testing: In Scenario 1, a 50% load step (an increase of 103 MW) was applied at Bus 28 at t = 1 s. In Scenario 2, the load at Bus 26 was disconnected (a reduction of 139 MW) at t = 1 s. In Scenario 3, a 5% load step (an increase of 55.2 MW) was applied at Bus 39 at t = 1 s. In Scenario 4, a 100% load step (an increase of 320 MW) was applied at Bus 15 at t = 1 s. The average deviation between the maximum and minimum estimated inertia values across the four disturbance scenarios was 0.18 s, which corresponded to 3.98% of the system's equivalent inertia (4.43 s). In addition, under six different operating conditions, the estimation error for the system's time-varying inertia remained within 2%. These findings demonstrated the strong adaptability of the method to different scenarios, operating conditions, and disturbance magnitudes. Finally, simulation tests were conducted using actual data from a provincial power grid in China. DC blocking and load disturbances were established as large- and small-disturbance scenarios, respectively. The results demonstrated that, under both conditions, the relative error in equivalent inertia estimation across all regions remained below 7%, with most errors below 3%. The computation time for all regional assessments across different scenarios consistently remained below 0.03 s, which fully satisfied the computational speed and accuracy requirements for online power system analysis and evaluation. Conclusions The proposed method demonstrated high effectiveness in regional inertia estimation across various scenarios, operating conditions, and disturbance scales. It exhibited considerable advantages in estimation accuracy, computational efficiency, and practical engineering applicability. We provide a reliable and efficient technical approach for online monitoring of power system inertia, supporting the secure and stable operation of power grids with increasingly high proportions of power electronic devices.
式中,N2为输入信号向量 x (n)的个数, x (i)为输入信号向量 x (n)中第i个数据的值。
由于期望输出 d (n)为原始信号的滤波方式在实际应用中无法实现,因此,本文提出一种基于自适应滤波的PMU数据测量噪声去除方式。输入信号依旧为 x (n),期望信号换为噪声信号,此时自适应滤波的输出信号向量 y (n)即为接近于期望信号噪声信号的数据,最后,用输入信号向量 x (n)减去输出信号向量 y (n)即可得到滤去噪声后的数据信号。
ZhangWuqi, WenYunfeng, ChiFangde,et al.Research framework and prospect on power system inertia estimation[J].Proceedings of the CSEE,2021,41(20):6842-6856.
ZhangWuqi, WenYunfeng, ChungC Y.Inertia security evaluation and application in low-inertia power systems[J].IEEE Transactions on Power Systems,2025,40(2):1725-1737. doi:10.1109/tpwrs.2024.3420786
[4]
InoueT, TaniguchiH, IkeguchiY,et al.Estimation of power system inertia constant and capacity of spinning-reserve support generators using measured frequency transients[J].IEEE Transactions on Power Systems,1997,12(1):136-143. doi:10.1109/59.574933
[5]
AshtonP M, SaundersC S, TaylorG A,et al.Inertia estimation of the GB power system using synchrophasor measurements[J].IEEE Transactions on Power Systems,2015,30(2):701-709. doi:10.1109/tpwrs.2014.2333776
[6]
KerdpholT, WatanabeM, NishikawaR,et al.Determining inertia of 60 Hz Japan power system using PMUs from power loss event[C]//Proceedings of the 2021 IEEE Texas Power and Energy Conference(TPEC).College Station:IEEE,2021:1-5. doi:10.1109/tpec51183.2021.9384932
[7]
LiuFanglei, BiTianshu, YanJiaming,et al.Area inertia estimation based on PMU synchronous measurements[J].Journal of North China Electric Power University,2020,47(3):19-26.
MaYanfeng, LiJinyuan, WangZijian,et al.Assessment method of regional equivalent inertia of new energy power system based on measured data[J].Transactions of China Electrotechnical Society,2024,39(17):5406-5421.
LiDongdong, ZhangJiale, XuBo,et al.Equivalent inertia assessment in renewable power system considering frequency distribution properties[J].Power System Technology,2020,44(8):2913-2921. doi:10.13335/j.1000-3673.pst.2019.1935
BestR J, BroganP V, MorrowD J.Power system inertia estimation using HVDC power perturbations[J].IEEE Transactions on Power Systems,2021,36(3):1890-1899. doi:10.1109/tpwrs.2020.3028614
[14]
TuttelbergK, KilterJ, WilsonD,et al.Estimation of power system inertia from ambient wide area measurements[J].IEEE Transactions on Power Systems,2018,33(6):7249-7257. doi:10.1109/tpwrs.2018.2843381
[15]
LiShichun, XiaZhixiong, ChengXuchang,et al.Continuous estimation method of power system inertia based on ambient disturbance[J].Proceedings of the CSEE,2020,40(14):4430-4439.
HuangSiwei, ZhangJunbo, ZengFanhong.Efficient online algorithm for fast inertia tracking of power system[J].High Voltage Engineering,2021,47(10):3519-3527.
PeiMing, YeLin, LuoYadi,et al.Inertia estimation method for power system with renewable energy considering spatio-temporal correlation of frequency response[J].Automation of Electric Power Systems,2024,48(8):53-66.
CaoBin, YuanShuai, LiuJiahao,et al.Power system online inertia estimation considering real-time clustering of frequency dynamic response[J].Power System Technology,2023,47(3):930-941.
BizzarriF, del GiudiceD, GrilloS,et al.Inertia estimation through covariance matrix[J].IEEE Transactions on Power Systems,2024,39(1):947-956. doi:10.1109/tpwrs.2023.3236059
[24]
WangBo, WangYu, ZhangSong,et al.Regional inertia estimation method for power system based on random data-driven subspace dynamic mode decomposition[J].Automation of Electric Power Systems,2024,48(10):78-86.
AEMC.National electricity rules Version 131 Chapter4[EB/OL].(2022-12-20) [2025-04-16].
[29]
LiYong, ChangFanrui, PengYanjian,et al.Evaluation method for node inertia distribution of power grids based on small disturbance frequency measurement data[J].Automation of Electric Power Systems,2024,48(13):50-59.
LuZongxiang, JiangJiheng, QiaoYing,et al.A review on generalized inertia analysis and optimization of new power systems[J].Proceedings of the CSEE,2023,43(5):1754-1776.
TanBendong, ZhaoJunbo, NettoM,et al.Power system inertia estimation:Review of methods and the impacts of converter-interfaced generations[J].International Journal of Electrical Power & Energy Systems,2022,134:107362. doi:10.1016/j.ijepes.2021.107362
[34]
ZhangXiangyu, HuJianfeng, FuYuan,et al.Virtual inertia demand and collaborative support of wind power and energy storage system[J].Transactions of China Electrotechnical Society,2024,39(3):672-685.
RamtharanG, JenkinsN, EkanayakeJ B.Frequency support from doubly fed induction generator wind turbines[J].IET Renewable Power Generation,2007,1(1):3-9. doi:10.1049/iet-rpg:20060019
[37]
LiShaolin, WangWeisheng, ZhangXing,et al.Impact of wind power on power system frequency and combined virtual inertia control[J].Automation of Electric Power Systems,2019,43(15):64-70. doi:10.7500/AEPS20190103005
WangSue, WuYongbin, XiongLiansong,et al.Virtual inertia control strategy for grid-tied photovoltaic power generation system[J].High Voltage Engineering,2020,46(11):3743-3751.
DasguptaS, ParamasivamM, VaidyaU,et al.Real-time monitoring of short-term voltage stability using PMU data[J].IEEE Transactions on Power Systems,2013,28(4):3702-3711. doi:10.1109/tpwrs.2013.2258946
[43]
XuJunyang, ZhangHongmei, ZhangKun.A variable step size LMS algorithm based on deep reinforcement learning[J].Chinese Journal of Scientific Instrument,2025,46(2):70-80.
LiuFanglei, XuGuoyi, WangFan,et al.Assessment method of system partition inertia based on differential calculation method[J].Automation of Electric Power Systems,2020,44(20):46-53.
AnJun, ShengShuai, ZhouYibo,et al.Evaluation of equivalent virtual inertia of wind farm based on measured data[J].Power System Technology,2023,47(5):1819-1829.