Objective During elevator ascent, electric energy is converted into positive mechanical energy by overcoming passengers' gravitational energy in the upward cabins. During descent, electric energy is converted into negative mechanical energy to balance passengers' gravitational energy in the downward cabins. This wastes the passengers' gravitational energy and the electric energy during cabin descent. In this study, we propose a new electrohydraulic hybrid drive system for a pedestrian overpass elevator that uses high-pressure/low-pressure accumulators and a photovoltaic power generation system to recycle and reuse the passengers' gravitational energy. Methods The proposed electrohydraulic hybrid drive system comprises a two-degree-of-freedom planetary gear train, a hydraulic drive system, an AC motor drive, and a photovoltaic power generation device. In the traction system, the planetary gear train drives the traction sheave and passenger cabins. Its two inputs are connected to the AC and hydraulic motors, and its output connects to the traction sheave. The planetary gear train enables three driving patterns of the traction sheave: 1) driven only by an AC motor, equivalent to a conventional elevator; 2) driven only by a hydraulic motor supplied by high-pressure (recycles solar energy) and low-pressure (recycles and reuses passengers' gravitational energy) accumulators; 3) driven by an AC motor and a hydraulic motor, which operates as a hybrid drive pattern. The hydraulic drive system uses the mechanical/hydraulic energy conversion function of hydraulic pumps/motors to convert the gravitational potential energy of the descending pedestrians into pressure energy and store it in a low-pressure accumulator. Three low-pressure accumulator levels are used to store the different energy levels converted from different levels of passengers' gravitational energy. The hydraulic energy stored in the low-pressure accumulator can also be converted to mechanical energy to lift the cabins. To enhance the energy transfer and storage efficiency of gravitational potential energy, three levels of low-pressure accumulators are employed to store the transferred gravitational potential energy. The rated pressure levels of the three low-pressure accumulators are 3 MPa, 5 MPa, and 7 MPa, corresponding to passenger load ranges of 0‒500 kg, 500‒1 000 kg, and 1 000‒2 000 kg, respectively. A photovoltaic power-generation device is installed on the top of the pedestrian overpass. The solar energy is directly converted to hydraulic energy and stored in the high-pressure accumulator, providing additional energy supplementation for the new electrohydraulic hybrid drive system. Three high-pressure accumulator levels are employed to store solar-generated energy. Comprehensive mathematical models considering the photovoltaic power generation device, accumulator, hydraulic pump/motor, and traction-wheel mechanical transmission system are established. Results and Discussions A new electrohydraulic hybrid drive system is designed. The maximum loads of cabin A and cabin B are 2 000 kg each. The height between the overpass pavement and ground is 5 m. The rated pressure of each high-pressure accumulator is 10 MPa. The high- and low-pressure accumulator volumes are 200 L and 100 L, respectively. The fixed-displacement pump's rated speed is 1 000 r/min, and the rated revolution speed of the DC motor is 1 000 r/min. The common power density of the photovoltaic board is 100‒150 W/m2. Taking the pedestrian overpass at Xi'an University of Technology in Xi'an, China, as an example, adding a photovoltaic power board would require an area of approximately 150 m2. The simulations are implemented using the AMESim software. Three types of working conditions are simulated using AMESim. 1) Under the high-pressure accumulator releasing pressure energy (cabin upward) condition, one high-pressure accumulator can supply the cabin with a 2 000 kg load 2‒3 times. The three levels of the low-pressure accumulator are designed to accommodate different amounts of gravitational energy. A low-pressure accumulator rated at 7 MPa can store 6 times the gravitational energy caused by 2 000 kg. The cabin can move from the ground to the overpass pavement at 1 m/s in approximately 6 s, providing an acceptable transitional operating velocity. 2) Under the low-pressure accumulator storing gravity potential energy (cabin downward) condition, the cabin's transition from startup to smooth operation occurs over 0‒1.0 s, and its transition from smooth operation to stopping occurs over 4.5‒5.9 s. The cabin maintains a stable operating speed of 1 m/s over 1.0‒4.5 s. The acceleration and deceleration curves also provide a comfortable ride for the passengers. The pressure energy converted from recycled gravitational energy is approximately one-sixth of that of a single low-pressure accumulator. 3) Under the hybrid drive condition, the cabin's operating-speed pattern is identical to that under the high-pressure accumulator drive mode, indicating that the hybrid drive mode works well. Fluctuations appear during the transitions from startup to smooth operation and from smooth operation to stopping. The AC motor's output power is approximately 12.3 kW, and it responds about 1.0 s faster than the hydraulic motor. From 40.0‒41.0 s, the AC motor is 100% in the hybrid drive mode. As cabin speed increases, the AC motor's output power decreases and the hydraulic motor's output power increases. The AC motor's output power exceeds that of the hydraulic motor from 41.0‒45.5 s. As cabin speed decreases, the AC motor's output power is lower than the hydraulic motor's output power from 45.5‒46.5 s. The output powers of the two motors are balanced at 45.25 s. Conclusions The main conclusions are summarized as follows: based on AMESim simulations, during high-pressure accumulator discharge of pressure energy (cabin ascent), the energy consumed to lift a cabin carrying 2 000 kg is approximately 156.00 kJ over 1.0 s. During the descent of a cabin carrying 2 000 kg, 38.71 kJ of gravitational energy is recycled over 1 s. The proposed elevator can complete 10 cycles continuously over 10 minutes. The energy conservation efficiency is 38.71/156 = 24.8%, excluding the solar energy from the photovoltaic board. The recycled solar energy converted into hydraulic pressure energy is 31.48 kW·h. Assuming the proposed elevator operates over an average sunshine duration of 3.8 h, the recycled solar energy produced over 10 minutes is 0.219 kW·h (788.4 kJ). Including the photovoltaic board's solar energy, energy conservation efficiency can reach (387.1+788.4)/1 560 = 75.3%. These results can serve as a reference for the innovative design and energy-saving operation of pedestrian overpass elevators.
KavianpourS, HaghighiF, SheykhfardA,et al.Assessing the risk of pedestrian crossing behavior on suburban roads using structural equation model[J].Journal of Traffic and Transportation Engineering(English Edition),2024,11(5):853‒866. doi:10.1016/j.jtte.2023.12.001
[2]
DingBao, ZhangYongming, PengXiyuan,et al.A hybrid approach for the analysis and prediction of elevator passenger flow in an office building[J].Automation in Construction,2013,35:69‒78. doi:10.1016/j.autcon.2013.03.003
[3]
JiahuiAng, YusupY, Ahmad‒ZakiS,et al.Comprehensive energy consumption of elevator systems based on hybrid approach of measurement and calculation in low- and high-rise buildings of tropical climate towards energy efficiency[J].Sustainability,2022,14(8):4779. doi:10.3390/su14084779
[4]
MaamirM, CharroufO, BetkaA,et al.Neural network power management for hybrid electric elevator application[J].Mathematics and Computers in Simulation,2020,167:155‒175. doi:10.1016/j.matcom.2019.09.008
[5]
ZhaoBin, QuanZhongyi, LiYunwei,et al.A hybrid-driven elevator system with energy regeneration and safety enhancement[J].IEEE Transactions on Industrial Electronics,2020,67(9):7715‒7726. doi:10.1109/tie.2019.2941141
[6]
LiuHang, LangBaohua.Design of the elevator feeding control system based on PWM rectifier[J].Ship Electronic Engineering,2019,39(1):60‒64.
WanJianru, HanWeiwei, HuangShaolun,et al.Research and application to super-capacitor for elevator energy-saving[J].Electric Machines & Control,2015,19(6):55‒60.
[9]
PlangklangB, KantawongS.Study of power generation for permanent magnet motor elevator by energy regenerative unit(EERU)[J].Energy Procedia,2014,56:591‒597. doi:10.1016/j.egypro.2014.07.197
TominagaS, SugaI, ArakiH,et al.Development of energy-saving elevator using regenerated power storage system[C]//Proceedings of the Power Conversion Conference-Osaka 2002.Osaka:IEEE,2002:890‒895.
[12]
MouYaorong, ShiRongliang, HuangJi,et al.Application and analysis of supercapacitor energy storage device in elevator energy saving[J].China Elevator,2023,34(3):13‒16.
QiGuanran, YangShuzhen, LiMin,et al.Study on traction elevator accumulator energy storage hydraulic energy saving system and capacitor energy consumption[J].Machine Tool & Hydraulics,2023,51(3):146‒150.
ChangXiaoqing, FengShuangchang.Research on energy-saving application of elevator energy feedback device[J].Hoisting and Conveying Machinery,2022(17):74‒77.
[17]
常晓清,冯双昌.电梯能量回馈装置的节能应用研究[J].起重运输机械,2022(17):74‒77.
[18]
DalalaZ, AlwahshT, SaadehO.Energy recovery control in elevators with automatic rescue application[J].Journal of Energy Storage,2021,43:103168. doi:10.1016/j.est.2021.103168
[19]
WangSujuan, WuXiaotao.Research on dispatching algorithm of elevator group control system[J].Modern Electronics Technique,2022,45(11):104‒107.
OuZhe.Analysis of energy-saving optimized dispatching control strategy for elevator group control system[J].Automation Application,2020,61(1):56‒58.
[22]
欧哲.电梯群控系统节能优化调度控制策略分析[J].自动化应用,2020,61(1):56‒58.
[23]
YangJian, LiuBo, ZhangTiezhu,et al.Application of energy conversion and integration technologies based on electro-hydraulic hybrid power systems:A review[J].Energy Conversion and Management,2022,272:116372. doi:10.1016/j.enconman.2022.116372
[24]
LiaoJunzhang, YangYang, LuoRonghua,et al.Energy management strategy of four-wheel drive SUV electric-hydraulic hybrid(EHH) power system based on optimal instantaneous efficiency[J].Sustainable Energy Technologies and Assessments,2022,52:102139. doi:10.1016/j.seta.2022.102139
[25]
FresiaP, RundoM, PadovaniD,et al.Combined speed control and centralized power supply for hybrid energy-efficient mobile hydraulics[J].Automation in Construction,2022,140:104337. doi:10.1016/j.autcon.2022.104337
[26]
ZhuXiaoming, HuaGuorong, YangLihong.Design of hydraulic system for telescopic jacks of hydraulic lift and its simulation research[J].China Elevator,2022,33(15):6‒10.
WangWenfeng, QinRunjie.Analysis on hydraulic control valve group of hydraulic lifts[J].Mechanical & Electrical Engineering Technology,2020,49(11):247‒249.
ZhangJie, ZhaoBin, HaoYunxiao.Research on energy-saving system of electro-hydraulic hybrid drive traction elevator based on variable displacement pump/motor[J].Chinese Hydraulics & Pneumatics,2020,44(9):153‒160.
FatehM M, AmerianM.Guaranteed-stability adaptive fuzzy control of a hydraulic elevator[J].International Journal of Intelligent Computing and Cybernetics,2013,6(3):252‒271.
[33]
CelikK F.A load temperature compensation method for green hydraulic lifts by means of inverters[J].Elevator World,2013,61(2):58‒71.