Objective A cable-stayed bridge is a structure in which the deck is supported by cables extending directly from one or more towers to the deck. Nonlinear material behavior and local vibrations of the stay cables may amplify the bridge's seismic response, potentially compromising structural safety and causing significant economic and social consequences. In this study, we quantify the effects of nonlinear cable vibrations on the dynamic response and principal vibration modes of the main girder‒tower system by accounting for the interactions among cable material nonlinearity, local cable vibrations, and the nonlinear dynamics of the girder‒tower system. Methods Nonlinearity in structural analysis generally refers to geometric nonlinearity and material nonlinearity. To account for the stress‒strain relationships of steel and concrete in reinforced concrete (RC) sections, we model the RC cross sections using fiber-based beam elements. Each section is divided into multiple concrete and steel fibers, allowing material nonlinearity to be captured. In contrast, stay cables are flexible components that adopt a catenary shape under self-weight and axial force. Cable sag due to self-weight affects the cable stiffness. Including self-weight in dynamic analyses increases computational complexity and may introduce substantial errors. Therefore, self-weight is excluded from the local vibration analysis of the cables, such that the element restoring force depends only on nodal displacements and the element axial force. Traditionally, the one‑element cable system (OECS) has been used to model stay cables in finite-element analyses, with each cable represented by a single element and its sag-induced nonlinearity approximated using an equivalent elastic modulus. However, to simulate the simultaneous local vibrations of the main girder, tower, and stay cables, we adopt a multi‑element cable system (MECS), in which each stay cable is discretized into multiple elements. Using a (115+165) m single-tower, single-cable, plane-asymmetric cable-stayed bridge as a case study, we develop a finite-element model using our in-house program NL_Beam_3D. The model incorporates cable segmentation and material nonlinearity, and its results are compared with those obtained using a conventional approximate method. Finally, we investigate the dynamic responses of the main girder, tower, and stay cables under moderate and strong earthquake excitations, accounting for both geometric and material nonlinearities. Results and Discussions Compared with the MIDAS Civil model, the key frequencies of the first nine modes calculated using the OECS model agree closely with those obtained from MIDAS Civil, except for the first mode. The initial axial force significantly influences the lower-order frequencies. We then developed a MECS model using our in-house program NL_Beam_3D to account for material nonlinearity and local cable vibrations. The differences in key frequencies between the MECS and conventional OECS models are less than 1.2%. Under moderate and strong earthquake excitations, certain stay cables exhibit large-amplitude nonlinear vibrations that affect the main girder and tower. For example, under moderate earthquake excitation, cables M4 and M14 exhibit noticeable local vibrations, with vertical amplitudes of ‒1.201 and 1.256 m, respectively, approximately two to three times those of the corresponding cables modeled without local vibration. Correspondingly, the axial force in cable M14 predicted by the MECS model is 6.49% higher than that predicted by the OECS model, indicating that local cable vibrations can substantially increase cable forces. Under strong earthquake excitation, nonlinear cable vibrations become more pronounced, with cables S16, M14, and M15 all exhibiting large-amplitude vibrations. The vertical amplitudes of cable M15 cable reach ‒1.936 and 2.130 m, representing increases of approximately 173.78% and 143.52%, respectively, relative to the corresponding amplitudes under moderate earthquake excitation. Meanwhile, the difference in the force of cable M14 increases from 6.49% under moderate earthquake excitation to 13.76% under strong earthquake excitation. These results indicate that increasing seismic intensity amplifies local cable vibrations and their effects on cable forces. The influence of nonlinear cable vibrations on the displacement and internal force responses of the main girder increases with seismic intensity. Under moderate earthquake excitation, the difference in vertical displacement at the midspan (2P‒3P) girder section between the MECS and OECS models is approximately 9.34%. Under strong earthquake excitation, this difference increases to 18.23%, indicating that local cable vibrations have a greater influence on girder deformation under stronger seismic excitation. Regarding the internal forces in the main girder, the out-of-plane bending moment is the most affected by local cable vibrations. At the 2P‒3P midspan section, the difference in out-of-plane bending moment between the MECS and OECS models reaches 15.76% under strong earthquake excitation, substantially exceeding the corresponding differences in axial force and in-plane bending moment. In contrast, the influence of nonlinear cable vibrations on the main tower response is relatively limited. Under moderate and strong earthquake excitation, the differences in longitudinal displacement at the tower's cable-anchorage zone between the MECS and OECS models range from 3.29% to 8.06% and from 3.09% to 7.50%, respectively. Regarding the internal forces in the main tower, the differences in axial force and in-plane bending moment remain within approximately 10%. These results indicate that, although local cable vibrations have a limited influence on the overall mechanical response of the tower, they still affect its local dynamic response. Conclusions The proposed MECS method, which discretizes stay cables into multiple elements and incorporates material nonlinearity, enables a more accurate analysis of the dynamic coupling between the stay cables and the main girder‒tower system. Neglecting local nonlinear cable vibrations in seismic analyses may lead to substantial underestimation of critical response quantities, including cable forces, girder displacements, and out-of-plane bending moments, particularly under strong earthquake excitation. Therefore, the MECS method is recommended for the seismic design and safety assessment of cable-stayed bridges..
ZhouXuhong, ZhangXigang.Thoughts on the development of bridge technology in China[J].Engineering,2019,5(6):1120‒1130. doi:10.1016/j.eng.2019.10.001
[2]
WangTao, BaiLunhua, WangLu,et al.Sudden cable breakage and train-bridge coupled vibration characteristics of a rail-road cable-stayed bridge [J].Journal of Traffic and Transportation Engineering,2026,26(9):175‒190.
LiangDong, XiaHongda, LiuJing.Analysis of the effects of local cable vibration on dynamic response of the cable-stayed bridge[J].Earthquake Resistant Engineering and Retrofitting,2019,41(1):96‒103.
WangZhiqian.Study on dynamic characteristics and nonlinear characteristics of multi-cable single beam coupled structures[J].Journal of Dynamics and Control,2023,21(4):41‒47.
CaetanoE, CunhaA, TaylorC A.Investigation of dynamic cable-deck interaction in a physical model of a cable-stayed bridge.Part Ⅰ:Modal analysis[J].Earthquake Engineering & Structural Dynamics,2000,29(4):481‒498. doi:10.1002/(sici)1096-9845(200004)29:4<481::aid-eqe918>3.0.co;2-1
[9]
WuQingxiong, TakahashiK, ChenBaochun.Dynamic characteristics of cable vibrations in a steel cable-stayed bridge using nonlinear enhanced MECS approach[J].Structural Engineering and Mechanics,2008,30(1):37‒66. doi:10.12989/sem.2008.30.1.037
[10]
WuQingxiong, ChenBaochun, WeiJiangang.A geometric nonlinear finite element analysis for 3d framed structures[J].Engineering Mechanics,2007,24(12):19‒24.
WuQingxiong, WangWenping, ChenBaochun.Finite element analysis for nonlinear vibration of cable-beam structure[J].Engineering Mechanics,2013,30(3):347‒354.
ZhanYuanhui.Experimental and Theoretical Study on Nonlinear Vibration of Cable-Stayed Structures[D].Fuzhou:Fuzhou University,2010.
[15]
詹远辉.索梁结构非线性振动试验和理论研究[D]. 福州:福州大学,2010.
[16]
GuanYongle, WangPeng, LiuBaiqiang.Parametric vibration analysis of stay cables using a super-thin elastic rod model[J].Journal of Dynamics and Control,2024,22(9):37‒44.
ZhengY, XuY L, GuQ.Nonlinear model updating of a reinforced concrete pedestrian cable-stayed bridge[J].Structural Control and Health Monitoring,2020,27(3):e2487. doi:10.1002/stc.2487
[19]
ChenKefan, LiYuan, HeShuanhai,et al.Numerical analysis of the cable-beam-cable coupled effect under the in-plane multiple internal resonances in cable-stayed bridges[J].Engineering Mechanics,2024,41(3):199‒213.
YaoChe, KangHoujun.Research of orthogonalities of modes and nonlinear vibration in cable-beam models[J].Journal of Central South University (Science and Technology),2021,52(10):3605‒3612.
ZhouDai, LiuJie, GuoJunhui,et al.Vibration response of cables in cable-stayed spatial structures under axial excitation[J].Engineering Mechanics,2007,24(3):34‒41.
BuZhanyu, XieXu, GouChanghuan.Effects of local cable vibration on the seismic response of cable-stayed bridges[J].Engineering Mechanics,2006,23(9):157‒166.
WangBo, ZhangHailong, XuFeng.Seismic time-history response analysis of cable-stayed bridge with local cable vibration[J].Journal of Southwest Jiaotong University,2008,43(4):441‒446.
YiJiang, YuDeen.Longitudinal damage of cable-stayed bridges subjected to near-fault ground motion pulses[J].Advances in Bridge Engineering,2021,2:12. doi:10.1186/s43251-021-00034-x
[30]
HuangXueyang, ZongZhouhong, XiaJian,et al.Nonlinear dynamic response analysis of cable-stayed bridge with single tower under strong earthquake excitations[J].Journal of Southeast University(Natural Science Edition),2015,45(2):354‒359.
LiQiao.State‒process correlation principle of structures[J].Bridge Construction,2020,50(5):22‒29.
[34]
李乔.结构的状态‒过程相关性原理[J].桥梁建设,2020,50(5):22‒29.
[35]
RisticD, YamadaY, IemuraH.Stress-strain based modeling of hysteretic structures under earthquake induced bending and varying axial loads[D].Kyoto:Kyoto University,1986. doi:10.2208/proee1957.18.329
[36]
WuQingxiong, ChenBaochun, WeiJiangang.A finite element method for analyzing material nonlinearity of concrete-filled steel tubular structures[J].Engineering Mechanics,2008,25(6):68‒74.
ShiYan, LiJun, QinHongguo,et al.Internal force state of long-span continuous rigid-frame bridge with high-rise piers and its effect on seismic response[J].Journal of Traffic and Transportation Engineering,2022,22(1):70‒81.
XuLihan, XuLueqin, YuanMaojun,et al.Influence of arching process on the peak seismie response position of long-span CFST arch bridge[J/OL].Journal of Jilin University(Engineering and Technology Edition),2025‒02‒10.
ErnstH J.Der E-modul von seilen unter berücksichtigung des durchhanges[J].Der Bauingenieur,1965,40(2):52‒55.
[46]
FujinoY, WarnitchaiP, PachecoB M. An experimental and analytical study of auto parametric resonance in a 3DOF model of cable-stayed-beam [J]. Nonlinear Dynamics, 1993, 4: 111‒138. doi:10.1007/bf00045250
[47]
中华人民共和国交通运输部,公路桥梁抗震设计规范 [S].北京:人民交通出版社: 2020.
[48]
ChenYongqi, LiuXihui, GongSili.The artificial earthquake ground motions compatible with standard response spectra[J].Journal of Building Structures,1981,2(4):34‒43.