地铁施工中地下车站防水施工技术分析
Analysis of waterproofing construction technology in underground station during subway construction
由于地下车站经常处于地下水位高、地层含水量大的环境,因此在整个施工和运营过程中都要承受着地下水的压力。从施工现场的经验来看,渗漏水的主要部位集中在施工缝、变形缝、穿墙管、螺栓孔洞及阴阳角等位置,如果没有及时处理,极易出现渗水通道,并且后期维修难度大。为此,我们结合了车站的明挖及暗挖常见渗漏情况,探讨相关的控制措施,旨在提高防水施工质量。
Underground stations are frequently exposed to high groundwater levels and saturated strata, subjecting them to continuous pressure throughout construction and operation. Field experience indicates that water infiltration primarily occurs at construction joints, expansion joints, wall-penetrating pipes, bolt holes, and corners. Without prompt remediation, these areas may develop leakage pathways, complicating subsequent repairs. To address this, we analyze common leakage patterns in both open-cut and closed-cut station construction methods and propose targeted control measures to enhance waterproofing quality.
| [1] |
青山雄. 地铁车站结构防水施工处理技术应用[J]. 中文科技期刊数据库(文摘版)工程技术, 2024(002):000. |
| [2] |
廖家全, 王军鹏. 地铁车站富水砂层地下连续墙渗漏水原因分析及预防治理[C]// 2024年全国工程建设行业施工技术交流会论文集(上册). 2024. |
| [3] |
王江华. 超深地铁车站地下连续墙受力性能及防水施工关键技术研究[J]. 建筑机械, 2025(5). |
| [4] |
李引雄. 基于双导洞PBA法的城市轨道交通地下暗挖车站施工技术[J]. 建筑技术, 2025(7). |
/
| 〈 |
|
〉 |