1.School of Future Cities,University of Science and Technology Beijing,Beijing 100083,China
2.The Key Laboratory of Urban Security and Disaster Engineering of Ministry of Education,Beijing University of Technology,Beijing 100124,China. Corresponding author: MU Zai-gen,E-mail: zgmu@ces. ustb. edu. cn
Through axial compression tests on L-shaped concrete-filled steel tube (CFST) columns with double corrugated steel plates (DCP-CFST), the axial compression stability bearing capacity and failure modes of this special-shaped column structure were studied. A nonlinear refined finite element model of the loaded specimens was established to simulate the axial compression loading process of DCP-CFST, as well as the effects of parameters such as the direction of initial defects, steel plate thickness, corrugated steel plate size, and height of the special-shaped column on the structural bearing capacity. The results show that DCP-CFST has high bearing capacity and good ductility; the corrugated steel plates provide effective confinement for the core concrete and can improve the local buckling performance of the structure; the magnitude and direction of initial defects have non-negligible effects on the bearing capacity and failure modes, but the influence of corrugation size is not significant. The accuracy of calculating the cross-sectional strength of DCP-CFST using the existing bearing capacity formulas in the CFST specifications was evaluated, and a stability coefficient calculation formula suitable for DCP-CFST was proposed.
图6为试件DCP-CFST在水平方向的位移计测量得到的结果.由于横截面的对称性,在加载过程中,试件水平变形值沿东西方向和南北方向大致相同,方向如图2所示.在承载力达到0.64Np之前没有明显的变形.当达到峰值承载力Np时,试件在H/2处的横向变形为10 mm.随着加载的继续,试件的变形迅速增大,向西北侧凸曲变形,而承载能力下降.当承载力为0.74Np时,西侧和北侧的最大变形约为50 mm.
YanXiang-yu, ZhangTian-zhu, ZhangXi, et al. Research on behavior of L-shaped columns composed of concrete-filled square steel tubes connected by H-shaped steel subjected to eccentric compression[J]. Building Structure, 2023, 53(3): 64-71.
TongJing-zhong, YuChao-qun, TongGen-shu, et al. Stability behavior of multi-celled corrugated-plate concrete filled steel tubular walls[J]. Journal of Building Structures, 2023, 44(5): 240-251, 285.
[12]
WangM Z, GuoY L, ZhuJ S, et al. Flexural-torsional buckling and design recommendations of axially loaded concrete-infilled double steel corrugated-plate walls with T-section[J]. Engineering Structures, 2020, 208: 110345.
[13]
ZhuJ S, GuoY L, WangM Z, et al. Strength design of concrete-infilled double steel corrugated-plate walls under uniform compressions[J]. Thin-Walled Structures, 2019, 141: 153-174.
[14]
LiX, LiaoX, LiZ Y, et al. Confinement mechanism of rectangular CFST components using double horizontally-corrugated steel plates[J]. Structures, 2023, 57: 105107.
[15]
阴冬冬 .新型矩形波纹钢管混凝土柱的轴压与偏压性能研究[D].徐州:中国矿业大学,2022.
[16]
YinDong-dong. Behavior of novel rectangular corrugated CFST columns under axial/eccentric compression [D]. Xuzhou: China University of Mining and Technology, 2022.
[17]
LiaoX, LiX, ZhaoS D, et al. Behavior of eccentrically loaded rectangular CFST components for shear walls using double horizontally-corrugated steel plates[J]. Engineering Structures, 2024, 303: 117470.
MuZai-gen, YangYu-qing. Experimental study on seismic behavior of oblique channel stiffened steel plate shear wall with side openings[J]. Journal of Building Structures, 2020, 41(6): 65-75.
[20]
ChenC C, KoJ W, HuangG L, et al. Local buckling and concrete confinement of concrete-filled box columns under axial load[J]. Journal of Constructional Steel Research, 2012, 78: 8-21.
Ministry of Housing and Urban-Rural Development of the People’s Republic of China. Standard for design of steel structures: GB 50017—2017 [S]. Beijing: China Architecture & Building Press, 2017.
HanLin-hai, TaoZhong. Study on behavior of concrete filled square steel tubes under axial load[J]. China Civil Engineering Journal, 2001, 34(2): 17-25.
[25]
高珺恺 .L形截面多腔钢管混凝土异形柱承载性能研究[D].北京:清华大学,2021.
[26]
GaoJun-kai. Study on bearing capacity of L-shaped irregularly concrete-filled steel tube columns [D]. Beijing: Tsinghua University, 2021.
China Association for Engineering Construction Standardization. Technical specification for structures with concrete-filled rectangular steel tube members: CECS 159—2004 [S]. Beijing: China Planning Press, 2004.
China Association for Engineering Construction Standardization. Technical specification for special-shaped column structure composed of concrete-filled rectangular steel tubes: T/ CECS 825—2021 [S]. Beijing: China Architecture & Building Press, 2021.
[31]
American Institute of Steel Constructuin. Specification for structural steel buildings: ANSI/AI SC 360—22 [S]. Chicago: American Institute of Steel Construction (AISC), 2022.
[32]
European Committee for Standardization. Eurocode 4: design of composite steel and concrete structures part 1-1: general rules and rules for buildings: EN 1994-1-1—2004 [S]. Brussels: European Committee for Standardization, 2004.
[33]
Standards Australia Committee. Bridge design part 6: steel and composite construction: AS 5100.6—2017 [S]. Sydney: Standards Australia, 2017.
Ministry of Housing and Urban-Rural Development of the People’s Republic of China. Technical code for concrete filled steel tubular structures: GB 50936—2014 [S]. Beijing: China Architecture & Building Press, 2014.
[36]
European Committee for Standardization. Eurocode 3: design of steel structures part 1-1: general rules and rules for buildings: EN 1993-1-1—2005 [S]. Brussels: European Committee for Standardization, 2005.