本文介绍了一种方形中空夹层钢管混凝土叠合(CECFDST)构件,通过对3组不同剪跨比的6个试件进行受弯试验,分析了其破坏模态、受力过程、变形规律以及剪跨比的影响。之后本文建立了有限元模型,并开展了受弯构件内力和参数分析,将有限元计算结果与试验结果进行了对比验证。研究结果表明CECFDST构件具有良好的受弯性能,各部件间协同工作;剪跨比对构件受弯过程和受弯性能的影响不明显,受弯承载力变化不到4.5%;增大含中空夹层钢管混凝土(CFDST)率Do/B和名义含钢率αn能够有效提高其力矩占比和强度发挥效率,外部配筋率ρ和αn应分别与Do/B保持正向和反向协调配置,建议0.50≤Do/B≤0.75、0.25≤空心率(χ)≤0.75、0.06≤αn≤0.20。
This paper proposes a novel composite member, namely a square concrete-encased concrete-filled double-skin steel tubular (CECFDST) member. Bending tests were first carried out on 3 groups of 6 CECFDST specimens under different shear-span ratios, to explore the failure modes, mechanical response processes, deformation laws, and influence of shear-span ratio. Then, a finite element model was developed to conduct the stress analysis and parametric analysis of the flexural members, and its accuracy was verified. The research results reveal that the CECFDST members exhibit good flexural behavior, showcasing good cooperation between the components. The influence of shear-span ratio on bending process and flexural performance was not significant, in which the change in Mu was less than 4.5%. Increasing the concrete-filled double-skin steel tube (CFDST) ratio (Do/B) and nominal steel ratio (αn) of the CFDST component could effectively improve the moment ratio and strength utilization efficiency. The external reinforcement ratio (ρ) and αn should be coordinated with Do/B in a positive and inverse relationship, respectively. It is recommended that 0.50≤Do/B≤0.75, 0.25≤χ≤0.75 and 0.06≤αn≤0.20.
中空夹层钢管混凝土叠合构件 / 受弯性能 / 受弯试验 / 剪跨比 / 有限元分析 / 构造要求
concrete-encased concrete-filled double-skin steel tube / flexural behavior / bending test / shear-span ratio / finite element analysis / configuration requirement
| [1] |
韩林海. 钢管混凝土结构—理论与实践[M]. 3版. 北京:科学出版社,2016:30-273. |
| [2] |
HAN Linhai. Concrete Filled Steel Tubular Structures—Theory and Practice[M]. 3rd ed. Beijing:Science Press,2016:30-273. (in Chinese) |
| [3] |
韩林海,牟廷敏,王法承, 钢管混凝土混合结构设计原理及其在桥梁工程中的应用[J]. 土木工程学报,2020,53(5):1-24. DOI:10.15951/j.tmgcxb.20200413.001. |
| [4] |
HAN Linhai,MU Tingmin,WANG Facheng,et al. Design theory of CFST (concrete-filled steel tubular) mixed structures and its applications in bridge engineering[J]. China Civil Engineering Journal,2020,53(5):1-24. DOI:10.15951/j.tmgcxb.20200413.001.(in Chinese) |
| [5] |
安钰丰. 方形钢管混凝土叠合压弯构件力学性能和设计方法研究[D]. 北京:清华大学,2015. |
| [6] |
AN Yufeng. Performance and design method of square concrete-encased CFST members under combined compression and bending[D]. Beijing:Tsinghua University,2015. (in Chinese) |
| [7] |
ZHAO H,WANG R,LAM D,et al. Behaviours of circular CFDST with stainless steel external tube:Slender columns and beams[J]. Thin-Walled Structures,2021,158:107172. DOI:10.1016/j.tws.2020.107172. |
| [8] |
LI W,WANG D,HAN L H. Behaviour of grout-filled double skin steel tubes under compression and bending:Experiments[J]. Thin-Walled Structures,2017,116:307-319. DOI:10.1016/j.tws.2017.02.029. |
| [9] |
AN Y F,HAN L H,ROEDER C. Flexural performance of concrete-encased concrete-filled steel tubes[J]. Magazine of Concrete Research,2014,66(5):249-267. DOI:10.1680/macr.13.00268. |
| [10] |
黄宏. 中空夹层钢管混凝土压弯构件的力学性能研究[D]. 福州:福州大学,2006. |
| [11] |
HUANG Hong. Behavior of concrete filled double-skin steel tubular beam-columns[D]. Fuzhou:Fuzhou University,2006. (in Chinese) |
| [12] |
刘涵,史艳莉,范家浩, 圆锥形中空夹层钢管混凝土纯弯构件受力性能研究[J]. 建筑钢结构进展,2021,23(5):9-17. DOI:10.13969/j.cnki.cn31-1893.2021.05.002. |
| [13] |
LIU Han,SHI Yanli,FAN Jiahao,et al. Research on the mechanical properties of tapered concrete-filled double skin steel tubular members subjected to pure bending load[J]. Progress in Steel Building Structures,2021,23(5):9-17. DOI:10.13969/j.cnki.cn31-1893.2021.05.002.(in Chinese) |
| [14] |
中华人民共和国住房和城乡建设部,中华人民共和国国家质量监督检验检疫总局.混凝土结构工程施工质量验收规范:GB 50204—2015[S]. 北京:中国建筑工业出版社,2015. |
| [15] |
Ministry of Housing and Urban-Rural Development of the People's Republic of China,General Administration of Quality Supervision,Inspection and Quarantine of the People's Republic of China. Code for Quality Acceptance of Concrete Structure Construction:GB 50204—2015[S]. Beijing:China Architecture & Building Press,2015. (in Chinese) |
| [16] |
中华人民共和国住房和城乡建设部,国家市场监督管理总局. 混凝土物理力学性能试验方法标准:GB/T 50081—2019[S]. 北京:中国建筑工业出版社,2019. |
| [17] |
Ministry of Housing and Urban-Rural Development of the People's Republic of China,State Administration for Market Regulation. Standard for Test Methods of Concrete Physical and Mechanical Properties:GB/T 50081—2019[S]. Beijing:China Architecture & Building Press,2019. (in Chinese) |
| [18] |
European Committee for Standardization. Eurocode 2. Design of Concrete Structures:BS EN 1992-1-1[S]. Brussels:European Committee for Standardization,2004. |
| [19] |
国家质量监督检验检疫总局,中国国家标准化管理委员会. 金属材料 拉伸试验 第1部分:室温试验方法:GB/T 228.1—2010[S]. 北京:中国标准出版社,2010. |
| [20] |
General Administration of Quality Supervision,Inspection and Quarantine of the People's Republic of China,Standardization Administration of the People's Republic of China. Metallic Materials - Tensile Testing- Part 1:Method of Test at Room Temperature:GB/T 228.1—2010[S]. Beijing:Standards Press of China,2010. (in Chinese) |
| [21] |
中华人民共和国住房和城乡建设部,中华人民共和国国家质量监督检验检疫总局. 混凝土结构试验方法标准:GB/T 50152—2012[S]. 北京:中国建筑工业出版社,2012. |
| [22] |
Ministry of Housing and Urban-Rural Development of the People's Republic of China,General Administration of Quality Supervision,Inspection and Quarantine of the People's Republic of China. Standard for Test Method of Concrete Structures:GB/T 50152—2012[S]. Beijing:China Architecture & Building Press,2012. (in Chinese) |
| [23] |
HAN L H. Flexural behaviour of concrete-filled steel tubes[J]. Journal of Constructional Steel Research,2004,60(2):313-337. DOI:10.1016/j.jcsr.2003.08.009. |
| [24] |
REN Q X,DING J N,WANG Q H,et al. Flexural behavior of square hollow steel-reinforced concrete members[J]. Archives of Civil and Mechanical Engineering,2022,22(1):34. DOI:10.1007/s43452-021-00361-w. |
| [25] |
中华人民共和国住房和城乡建设部,中华人民共和国国家质量监督检验检疫总局. 混凝土结构设计规范:GB 50010—2010[S]. 北京:中国建筑工业出版社,2011. |
| [26] |
Ministry of Housing and Urban-Rural Development of the People's Republic of China,General Administration of Quality Supervision,Inspection and Quarantine of the People's Republic of China. Code for Design of Concrete Structures:GB 50010—2010[S]. Beijing:China Architecture & Building Press,2011. (in Chinese) |
| [27] |
REN Q X,DING J N,WANG Q H,et al. Behavior of slender square hollow steel-reinforced concrete columns under eccentric compression[J]. Journal of Building Engineering,2021,43:103133. DOI:10.1016/j.jobe.2021.103133. |
| [28] |
中国工程建设标准化协会标准. 钢管混凝土加劲混合结构技术规程:T/CECS 663—2020[S]. 北京:中国建筑工业出版社,2020. |
| [29] |
China Association for Engineering Construction Standardization. Technical Specification for Concrete-encased Concrete-filled Steel Tubular Structures:T/CECS 663—2020[S]. Beijing:China Architecture & Building Press,2020.(in Chinese) |
| [30] |
中国土木工程学会. 中空夹层钢管混凝土结构技术规程:T/CCES 7—2020[S]. 北京:中国建筑工业出版社,2020. |
| [31] |
China Civil Engineering Society. Technical Specification for Concrete-filled Double Skin Steel Tubular Structures:T/CCES 7—2020[S]. Beijing:China Architecture & Building Press,2020. (in Chinese) |
国家自然科学基金(51808351)
辽宁省应用基础研究计划(2022JH2/101300130)
辽宁省“兴辽英才计划”项目(XLYC1902027)
辽宁省教育厅博士启动项目(LJ212410153011)
辽宁省科学技术计划(2024-BS-121)
/
| 〈 |
|
〉 |