目的 探讨基于深度学习图像重建(DLIR)的能谱CT虚拟平扫(VUE)在腹部增强扫描中对图像质量和病灶检出率的影响。方法 收集2025年5~7月在陕西中医药大学附属医院行全腹CT平扫及2期(动脉、门脉期)增强扫描的受检者共50例,采用能谱GSI模式进行扫描并重建ASiR-V 40%(120 kVp-like)图像作为真实平扫(TUE),将两期增强扫描数据联合中、高等级DLIR(DLIR-M、DLIR-H)重建出4组VUE图像。测量比较5组图像的CT值、噪声(SD)、信噪比(SNR)、对比噪声比(CNR)及病灶检出率,并采用李克特5分法对5组图像质量进行评分。观察者一致性采用Kappa检验。采用单因素方差分析和Kruskal-Wallis H检验比较5组图像的主客观评价指标,采用卡方检验比较5组图像的病变检出率。结果 TUE与4组VUE间的CT值差异无统计学意义(P>0.05);4组VUE较TUE具有更低的SD、更高的SNR及CNR(P<0.05)。观察者对5组图像质量评分一致性较好(k均>0.8),其中静脉期-VUE-DLIR高等级组的图像质量评分最高,与TUE相比差异有统计学意义(P<0.001)。5组图像在病灶检出率之间的差异无统计学意义(P>0.05)。VUE+两期扫描有效剂量减少约33.35%,有效剂量ED为10.71±3.27 mSv。结论 基于DLIR算法的腹部VUE图像能够在不降低病灶检出率的情况下显著提升图像质量,提示使用DLIR-H重建的VUEV图像具有替代真实平扫以减少辐射剂量的潜在价值。
Objective To explore the impact of virtual unenhanced (VUE) of spectral CT based on deep learning image reconstruction (DLIR) on image quality and lesion detection rates in contrast-enhanced abdominal CT scanning. Methods A total of 50 patients who underwent unenhanced and dual-phase (arterial and portal venous phases) contrast-enhanced abdominal CT scans using the spectral GSI mode from May to July 2025 were collected in Affiliated Hospital of Shaanxi University of Chinese Medicine. True unenhanced (TUE) images were reconstructed with ASiR-V 40% (120 kVp-like). Four groups of VUE images were reconstructed using medium and high level DLIR (DLIR-M and DLIR-H) based on the dual-phase contrast-enhanced data. The CT values, noise (SD), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and lesion detection rates of the five groups were measured and compared, and the 5-point Likert method was adopted to evaluate the overall image. Inter-observer agreement was assessed using the Kappa test. One-way ANOVA analysis and Kruskal-WallisH test were used to compare the subjective and objective evaluation indexes of the five groups.The lesion detection rates of the five groups were compared using the chi-square test. Results There was no statistically significant difference in CT values between TUE and the four VUE groups (P>0.05). The four VUE groups had lower SD, higher SNR and CNR than TUE (allP< 0.05). Inter-observer agreement for image quality scores was good (all Kappa>0.8), and the image quality score of the VUEV-H group was the highest, showing a statistically significant difference compared with TUE (P<0.001). There was no statistically significant difference in lesion detection rates among the five groups(P>0.05). The effective dose (ED) of VUE combined with dual-phase scanning was reduced by approximately 33.35%, and the ED was (10.71±3.27) mSv. Conclusion The abdominal VUE image based on DLIR can significantly improve image quality without reducing the lesion detection rates. It is suggested that the VUEV images reconstructed using DLIR-H have the potential value of replacing TUE scans to reduce radiation doses.
| [1] |
|
| [2] |
|
| [3] |
|
| [4] |
|
| [5] |
|
| [6] |
|
| [7] |
|
| [8] |
|
| [9] |
|
| [10] |
|
| [11] |
|
| [12] |
|
| [13] |
|
| [14] |
|
| [15] |
王晓霞, 钟玉敏, 薛潋滟, |
| [16] |
|
| [17] |
|
| [18] |
|
| [19] |
|
| [20] |
|
| [21] |
|
| [22] |
|
| [23] |
|
| [24] |
|
| [25] |
|
| [26] |
张艺腾, 夏春潮, 曾令明, |
| [27] |
|
| [28] |
|
| [29] |
|
| [30] |
|
| [31] |
|
| [32] |
|
咸阳市科技局秦创原中医药产业创新聚集区项目(L2024-QCY-ZYYJJQ-Y11)
/
| 〈 |
|
〉 |